An ultra-light helium cooled pixel detector for the Mu3e experiment
Authors:
Thomas Theodor Rudzki,
Heiko Augustin,
David Maximilian Immig,
Ruben Kolb,
Lukas Mandok
Abstract:
The Mu3e experiment searches for the lepton flavour violating decay $μ^+ \rightarrow e^+ e^- e^+$ with an ultimate aimed sensitivity of $1$ event in $10^{16}$ decays. To achieve this goal, the experiment must minimize the material budget per tracking layer to $X/X_0\approx 0.1\,\%$ and use gaseous helium as coolant. The pixel detector uses High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) whi…
▽ More
The Mu3e experiment searches for the lepton flavour violating decay $μ^+ \rightarrow e^+ e^- e^+$ with an ultimate aimed sensitivity of $1$ event in $10^{16}$ decays. To achieve this goal, the experiment must minimize the material budget per tracking layer to $X/X_0\approx 0.1\,\%$ and use gaseous helium as coolant. The pixel detector uses High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) which are thinned down to $50\, μm$. Both helium cooling and HV-MAPS are a novelty for particle detectors.
Here, the work on successfully cooling a pixel tracker using gaseous helium is presented. The thermal studies focus on the two inner tracking layers, the Mu3e vertex detector, and the first operation of a functional thin pixel detector cooled with gaseous helium. The approach, which circulates gaseous helium under ambient pressure conditions with a gas temperature around $0\,�C$ using a miniature turbo compressor with a mass flow of $2\,g/s$ allows the vertex detector to operate below $70\,�C$ at heat densities of up to $350\,mW/cm^2$. Finally, performance data of the final HV-MAPS used by Mu3e, the MuPix11, is presented. These results demonstrate the feasibility of using HV-MAPS combined with gaseous helium as a coolant for an ultra-thin pixel detector exploring new frontiers in lepton flavor.
△ Less
Submitted 27 July, 2023;
originally announced July 2023.
-
TelePix -- A fast region of interest trigger and timing layer for the EUDET Telescopes
Authors:
Heiko Augustin,
Sebastian Dittmeier,
Jan Hammerich,
Adrian Herkert,
Lennart Huth,
David Immig,
Ivan Perić,
André Schöning,
Adriana Simancas,
Marcel Stanitzki,
Benjamin Weinläder
Abstract:
Test beam facilities are essential to study the response of novel detectors to particles. At the DESY II Test Beam facility, users can test their detectors with an electron beam with a momentum from 1-6 GeV. To track the beam particles, EUDET-style telescopes are provided in each beam area. They provide excellent spatial resolution, but the time resolution is limited by the rolling shutter archite…
▽ More
Test beam facilities are essential to study the response of novel detectors to particles. At the DESY II Test Beam facility, users can test their detectors with an electron beam with a momentum from 1-6 GeV. To track the beam particles, EUDET-style telescopes are provided in each beam area. They provide excellent spatial resolution, but the time resolution is limited by the rolling shutter architecture to a precision of approximately 230 $μ$s. Since the demand on particle rates -- and hence track multiplicities -- is increasing timing is becoming more relevant. DESY foresees several upgrades of the telescopes. TelePix is an upgrade project to provide track timestamping with a precision of better than 5 ns and a configurable region of interest to trigger the telescope readout. Small scale prototypes have been characterised in laboratory and test beam measurements. Laboratory tests with an injection corresponding to 2300 electrons show a S/N of above 20. Test beam characterization shows efficiencies of above 99% over a threshold range of more than 100 mV and time resolutions of 2.4 ns at low noise rates.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Upgrading the Beam Telescopes at the DESY II Test Beam Facility
Authors:
H. Augustin,
R. Diener,
S. Dittmeier,
P. M. Freeman,
J. Hammerich,
A. Herkert,
L. Huth,
D. Immig,
U. Krämer,
N. Meyners,
I. Perić,
O. Schäfer,
A. Schöning,
A. Simancas,
M. Stanitzki,
D. Stuart,
B. Weinläder
Abstract:
The DESY II Test Beam Facility is a key infrastructure for modern high energy physics detector development, providing particles with a small momentum spread in a range from 1 to 6 GeV to user groups e.g. from the LHC experiments and Belle II as well as generic detector R&D. Beam telescopes are provided in all three test beam areas as precise tracking reference without time stamping, with triggered…
▽ More
The DESY II Test Beam Facility is a key infrastructure for modern high energy physics detector development, providing particles with a small momentum spread in a range from 1 to 6 GeV to user groups e.g. from the LHC experiments and Belle II as well as generic detector R&D. Beam telescopes are provided in all three test beam areas as precise tracking reference without time stamping, with triggered readout and a readout time of > 115 $μ$s. If the highest available rates are used, multiple particles are traversing the telescopes within one readout frame, thus creating ambiguities that cannot be resolved without additional timing layers. Several upgrades are currently investigated and tested: Firstly, a fast monolithic pixel sensor, the TelePix, to provide precise track timing and triggering on a region of interest is proposed to overcome this limitation. The TelePix is a 180 nm HV-CMOS sensor that has been developed jointly by DESY, KIT and the University of Heidelberg and designed at KIT. In this publication, the performance evaluation is presented: The difference between two amplifier designs is evaluated. A high hit detection efficiency of above 99.9 % combined with a time resolution of below 4 ns at negligible pixel noise rates is determined. Finally, the digital hit output to provide region of interest triggering is evaluated and shows a short absolute delay with respect to a traditional trigger scintillator as well as an excellent time resolution. Secondly, a fast LGAD plane has been proposed to provide a time resolution of a few 10 ps, which is foreseen to drastically improve the timing performance of the telescope. Time resolutions of below 70 ps have been determined in collaboration with the University of California, Santa Barbara.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
The Mu3e experiment: Toward the construction of an HV-MAPS vertex detector
Authors:
Thomas Rudzki,
Heiko Augustin,
Marin Deflorin,
Sebastian Dittmeier,
Florian Frauen,
David Maximilian Immig,
Dohun Kim,
Frank Meier Aeschbacher,
Annie Meneses González,
Marius Menzel,
Ivan Perić,
Sebastian Preuß,
André Schöning,
Luigi Vigani,
Alena Weber,
Benjamin Weinläder
Abstract:
The Mu3e experiment searches for the lepton flavor violating decay $μ^+~\rightarrow~e^+~e^+~e^-$ with an ultimate aimed sensitivity of 1 event in $10^{16}$ decays. This goal can only be achieved by reducing the material budget per tracking layer to $X/X_0 \approx 0.1 \%$. High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) which are thinned to $50\ μm$ serve as sensors. Gaseous helium is chosen…
▽ More
The Mu3e experiment searches for the lepton flavor violating decay $μ^+~\rightarrow~e^+~e^+~e^-$ with an ultimate aimed sensitivity of 1 event in $10^{16}$ decays. This goal can only be achieved by reducing the material budget per tracking layer to $X/X_0 \approx 0.1 \%$. High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) which are thinned to $50\ μm$ serve as sensors. Gaseous helium is chosen as coolant.
Results of recent studies related to the sensor prototypes, the helium cooling, and module prototyping are presented. The recent chip submission MuPix10 has proven its functionality regarding efficiency and time resolution. The helium cooling system for the inner tracker could be verified using a full-scale prototype. A complete prototype equipped with MuPix10 chips will be tested inside the Mu3e magnet in summer 2021.
△ Less
Submitted 7 June, 2021;
originally announced June 2021.
-
MuPix10: First Results from the Final Design
Authors:
Heiko Augustin,
Niklaus Berger,
Sebastian Dittmeier,
David Maximilian Immig,
Dohun Kim,
Lukas Mandok,
Annie Meneses Gonzalez,
Marius Menzel,
Lars Olivier Sebastian Noehte,
Ivan Perić,
Alexander Schmidt,
André Schöning,
Luigi Vigani,
Alena Weber,
Benjamin Weinläder
Abstract:
Many years of research and development of High Voltage Monolithic Active Pixel Sensors (HVMAPS) have culminated in the final design for the Mu3e pixel sensor. MuPix10 is a fully monolithic sensor with an active pixel matrix size of $20\times20\,\mathrm{mm}^2$ produced in the $180\,\mathrm{nm}$ HV-CMOS process at TSI Semiconductors. The pixel size is $80\times80\,\mathrm{μm}^2$. Hits are read out u…
▽ More
Many years of research and development of High Voltage Monolithic Active Pixel Sensors (HVMAPS) have culminated in the final design for the Mu3e pixel sensor. MuPix10 is a fully monolithic sensor with an active pixel matrix size of $20\times20\,\mathrm{mm}^2$ produced in the $180\,\mathrm{nm}$ HV-CMOS process at TSI Semiconductors. The pixel size is $80\times80\,\mathrm{μm}^2$. Hits are read out using a column-drain architecture and sent over up to four serial links with up to $1.6\,\left.\mathrm{Gbit}\middle/\mathrm{s}\right.$ each. By means of DC/DC converters and exclusive usage of on-chip biasing, MuPix10 is fully operable with a minimal set of electrical connections. This is an integral requirement by the Mu3e experiment since it enables the construction of ultra-thin pixel modules with $0.1\,$% of a radiation length per layer. First results from lab characterisation and testbeam campaigns are presented.
△ Less
Submitted 11 December, 2020; v1 submitted 10 December, 2020;
originally announced December 2020.
-
The Mu3e Data Acquisition
Authors:
Heiko Augustin,
Niklaus Berger,
Alessandro Bravar,
Konrad Briggl,
Huangshan Chen,
Simon Corrodi,
Sebastian Dittmeier,
Ben Gayther,
Lukas Gerritzen,
Dirk Gottschalk,
Ueli Hartmann,
Gavin Hesketh,
Marius K�ppel,
Samer Kilani,
Alexandr Kozlinskiy,
Frank Meier Aeschbacher,
Martin M�ller,
Yonathan Munwes,
Ann-Kathrin Perrevoort,
Stefan Ritt,
André Schöning,
Hans-Christian Schultz-Coulon,
Wei Shen,
Luigi Vigani,
Dorothea vom Bruch
, et al. (3 additional authors not shown)
Abstract:
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ^+\to e^+e^-e^+$ with a sensitivity of one in 10$^{16}$ muon decays. The first phase of the experiment is currently under construction at the Paul Scherrer Institute (PSI, Switzerland), where beams with up to 10$^8$ muons per second are available. The detector will consist of an ultra-thin pixel tracker made from High…
▽ More
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ^+\to e^+e^-e^+$ with a sensitivity of one in 10$^{16}$ muon decays. The first phase of the experiment is currently under construction at the Paul Scherrer Institute (PSI, Switzerland), where beams with up to 10$^8$ muons per second are available. The detector will consist of an ultra-thin pixel tracker made from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented by scintillating tiles and fibres for precise timing measurements. The experiment produces about 100 Gbit/s of zero-suppressed data which are transported to a filter farm using a network of FPGAs and fast optical links. On the filter farm, tracks and three-particle vertices are reconstructed using highly parallel algorithms running on graphics processing units, leading to a reduction of the data to 100 Mbyte/s for mass storage and offline analysis. The paper introduces the system design and hardware implementation of the Mu3e data acquisition and filter farm.
△ Less
Submitted 20 January, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Technical design of the phase I Mu3e experiment
Authors:
K. Arndt,
H. Augustin,
P. Baesso,
N. Berger,
F. Berg,
C. Betancourt,
D. Bortoletto,
A. Bravar,
K. Briggl,
D. vom Bruch,
A. Buonaura,
F. Cadoux,
C. Chavez Barajas,
H. Chen,
K. Clark,
P. Cooke,
S. Corrodi,
A. Damyanova,
Y. Demets,
S. Dittmeier,
P. Eckert,
F. Ehrler,
D. Fahrni,
S. Gagneur,
L. Gerritzen
, et al. (80 additional authors not shown)
Abstract:
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the p…
▽ More
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.
△ Less
Submitted 26 August, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
MuPix and ATLASPix -- Architectures and Results
Authors:
A. Schöning,
J. Anders,
H. Augustin,
M. Benoit,
N. Berger,
S. Dittmeier,
F. Ehrler,
A. Fehr,
T. Golling,
S. Gonzalez Sevilla,
J. Hammerich,
A. Herkert,
L. Huth,
G. Iacobucci,
D. Immig,
M. Kiehn,
J. Kröger,
F. Meier,
A. Meneses Gonzalez,
A. Miucci,
L. O. S. Noehte,
I. Peric,
M. Prathapan,
T. Rudzki,
R. Schimassek
, et al. (7 additional authors not shown)
Abstract:
High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being dev…
▽ More
High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being developed for LHC applications with a triggered readout. Both variants have a fully monolithic design including state machines, clock circuitries and serial drivers. Several prototypes and design variants were characterised in the lab and in testbeam campaigns to measure efficiencies, noise, time resolution and radiation tolerance. Results from recent MuPix and ATLASPix prototypes are presented and prospects for future improvements are discussed.
△ Less
Submitted 17 February, 2020;
originally announced February 2020.
-
EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes
Authors:
P. Ahlburg,
S. Arfaoui,
J. -H. Arling,
H. Augustin,
D. Barney,
M. Benoit,
T. Bisanz,
E. Corrin,
D. Cussans,
D. Dannheim,
J. Dreyling-Eschweiler,
T. Eichhorn,
A. Fiergolski,
I. -M. Gregor,
J. Grosse-Knetter,
D. Haas,
L. Huth,
A. Irles,
H. Jansen,
J. Janssen,
M. Keil,
J. S. Keller,
M. Kiehn,
H. J. Kim,
J. Kroll
, et al. (32 additional authors not shown)
Abstract:
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed…
▽ More
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
△ Less
Submitted 18 November, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Performance of the large scale HV-CMOS pixel sensor MuPix8
Authors:
H. Augustin,
N. Berger,
C. Blattgerste,
S. Dittmeier,
F. Ehrler,
C Grzesik,
J. Hammerich. A. Herkert,
L. Huth,
D. Immig,
A. Kozlinskiy,
M. Köppel,
J. Kröger,
F. Meier,
A. Meneses Gonzales,
M. Müller,
L. Noehte,
I. Perić,
M. Prathapan,
T. Rudzki,
R. Schimassek,
A. Schöning,
I. Sorokin,
F. Stieler,
A. Tyukin,
T. Wagner
, et al. (4 additional authors not shown)
Abstract:
The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers o…
▽ More
The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of $50\, μ\text{m}$ thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a $1\,\text{T}$ magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detectors provide sub-nanosecond time resolution. The MuPix8 chip is the first large scale prototype, proving the scalability of the HV-MAPS technology. It is produced in the AMS aH18 $180\, \text{nm}$ HV-CMOS process. It consists of three sub-matrices, each providing an untriggered datastream of more than $10\,\text{MHits}/\text{s}$. The latest results from laboratory and testbeam characterisation are presented, showing an excellent performance with efficiencies $>99.6\,\text{\%}$ and a time resolution better than $10\, \text{ns}$ achieved with time walk correction.
△ Less
Submitted 22 May, 2019;
originally announced May 2019.
-
Electrical characterization of AMS aH18 HV-CMOS after neutrons and protons irradiation
Authors:
D M S Sultan,
Sergio Gonzalez Sevilla,
Didier Ferrere,
Giuseppe Iacobucci,
Ettore Zaffaroni,
Winnie Wong,
Mateus Vicente Barrero Pinto,
Moritz Kiehn,
Mridula Prathapan,
Felix Ehrler,
Ivan Peric,
Antonio Miucci,
John Kenneth Anders,
Armin Fehr,
Michele Weber,
Andre Schoening,
Adrian Herkert,
Heiko Augustin,
Mathieu Benoit
Abstract:
In view of the tracking detector application to the ATLAS High Luminosity LHC (HL-LHC) upgrade, we have developed a new generation of High Voltage CMOS (HV-CMOS) monolithic pixel-sensor prototypes featuring the AMS aH18 (180 nm) commercial CMOS technology. By fully integrating both analog and digital readout-circuitry on the same particle-detecting substrate, current challenges of hybrid sensor te…
▽ More
In view of the tracking detector application to the ATLAS High Luminosity LHC (HL-LHC) upgrade, we have developed a new generation of High Voltage CMOS (HV-CMOS) monolithic pixel-sensor prototypes featuring the AMS aH18 (180 nm) commercial CMOS technology. By fully integrating both analog and digital readout-circuitry on the same particle-detecting substrate, current challenges of hybrid sensor technologies, i.e., larger readout input-capacitance, lower production-yield, and higher production and integration cost, can be downscaled. The large electrode design using high-resistivity substrates actively helps to mitigate the charge-trapping effects, making these chips radiation hard. The surface and bulk damage induced in high irradiation environment change the effective doping concentration of the device, which modulates high electric fields as the reverse-bias voltage increases. This effect can cause high leakage current and premature electrical breakdown, driven by impact ionization. In order to assess the characteristics of heavily irradiated samples, we have carried out dedicated campaigns on ATLASPix1 chips that included irradiations of neutrons and protons, made at different facilities. Here, we report on the electrical characterization of the irradiated samples at different ambient conditions, also in comparison to their pre-irradiation properties. Results demonstrate that hadron irradiated devices can be safely operated at a voltage high enough to allow for high efficiency, up to the fluence of 2E15 neq/cm2, beyond the radiation levels (TID and NIEL) expected in the outermost pixel layers of the new ATLAS tracker for HL-LHC.
△ Less
Submitted 28 May, 2020; v1 submitted 15 February, 2019;
originally announced February 2019.
-
Spatio-temporal modelling of forest monitoring data: Modelling German tree defoliation data collected between 1989 and 2015 for trend estimation and survey grid examination using GAMMs
Authors:
Nadine Eickenscheidt,
Nicole H. Augustin,
Nicole Wellbrock
Abstract:
Spatio-temporal modelling of tree defoliation data of German forest condition survey is presented. In the present study generalized additive mixed models were used to estimate the spatio-temporal trends of defoliation of the main tree species from 1989 to 2015 and to examine the suitability of different monitoring grid resolutions. Although data has been collected since 1989, this is the first tim…
▽ More
Spatio-temporal modelling of tree defoliation data of German forest condition survey is presented. In the present study generalized additive mixed models were used to estimate the spatio-temporal trends of defoliation of the main tree species from 1989 to 2015 and to examine the suitability of different monitoring grid resolutions. Although data has been collected since 1989, this is the first time the spatio-temporal modelling for entire Germany has been carried out. Besides the space-time component, stand age showed a significant effect on defoliation. The mean age and the species-specific relation between defoliation and age determined the general level of defoliation whereas fluctuations of defoliation were primarily related to weather conditions. The study indicates a strong association between drought stress and defoliation of all four main tree species. Besides direct effects of weather conditions, indirect effects seem to play a further role. Defoliation of the comparably drought-tolerant species pine and oak was primarily affected by insect infestations following drought whereas considerable time for regeneration was required by beech following drought stress and recurring substantial fructification. South-eastern Germany has emerged as the region with the highest defoliation since the drought year 2003. This region was characterized by the strongest water deficits in 2003 compared to the long-term reference period. The present study gives evidence that the focus has moved from air pollution to climate change. Furthermore, the spatio-temporal model was used to carry out a simulation study to compare different survey grid resolutions. This grid examination indicated that an 8 x 8 km grid instead of the standard 16 x 16 km grid is necessary for spatio-temporal trend estimation and for detecting hot-spots in defoliation in space and time, especially regarding oak.
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Efficiency and timing performance of the MuPix7 high-voltage monolithic active pixel sensor
Authors:
Heiko Augustin,
Niklaus Berger,
Sebastian Dittmeier,
Carsten Grzesik,
Jan Hammerich,
Ulrich Hartenstein,
Qinhua Huang,
Lennart Huth,
David Maximilian Immig,
Moritz Kiehn,
Alexandr Kozlinskiy,
Frank Meier Aeschbacher,
Annie Meneses González,
Ivan Perić,
Ann-Kathrin Perrevoort,
Andr� Sch�ning,
Shruti Shrestha,
Dorothea vom Bruch,
Frederik Wauters,
Dirk Wiedner
Abstract:
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the DESY electron test beam, we demonstrate an efficiency of 99.3% and a time resolution of 14 ns. The efficiency and time resolution are studied with sub-pixel resol…
▽ More
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the DESY electron test beam, we demonstrate an efficiency of 99.3% and a time resolution of 14 ns. The efficiency and time resolution are studied with sub-pixel resolution and reproduced in simulations.
△ Less
Submitted 30 June, 2018; v1 submitted 5 March, 2018;
originally announced March 2018.
-
Irradiation study of a fully monolithic HV-CMOS pixel sensor design in AMS 180 nm
Authors:
H. Augustin,
N. Berger,
S. Dittmeier,
J. Hammerich,
A. Herkert,
L. Huth,
D. Immig,
J. Kröger,
F. Meier,
I. Perić,
A. -K. Perrevoort,
A. Schöning,
D. vom Bruch,
D. Wiedner
Abstract:
High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. It is the first fully monolithic HV-CMOS pixel sensor…
▽ More
High-Voltage Monolithic Active Pixel Sensors (HV-MAPS) based on the 180 nm HV-CMOS process have been proposed to realize thin, fast and highly integrated pixel sensors. The MuPix7 prototype, fabricated in the commercial AMS H18 process, features a fully integrated on-chip readout, i.e. hit-digitization, zero suppression and data serialization. It is the first fully monolithic HV-CMOS pixel sensor that has been tested for the use in high irradiation environments like HL-LHC. We present results from laboratory and test beam measurements of MuPix7 prototypes irradiated with neutrons (up to $5.0\cdot10^{15}{\,\rm{n}_{\rm{eq}}/cm^2}$) and protons (up to $7.8\cdot 10^{15} \,\rm{protons}/cm^2$) and compare the performance with non-irradiated sensors. Efficiencies well above 90 % at noise rates below 200 Hz per pixel are measured. A time resolution better than 22 ns is measured for all tested settings and sensors, even at the highest irradiation fluences. The data transmission at 1.25 Gbit/s and the on-chip PLL remain fully functional.
△ Less
Submitted 5 June, 2018; v1 submitted 11 December, 2017;
originally announced December 2017.
-
The MuPix Telescope: A Thin, high Rate Tracking Telescope
Authors:
H. Augustin,
N. Berger,
S. Dittmeier,
C. Grzesik,
J. Hammerich,
Q. Huang,
L. Huth,
M. Kiehn,
A. Kozlinskiy,
F. Meier,
I. Perić,
A. -K. Perrevoort,
A. Schöning,
D. vom Bruch,
F. Wauters,
D. Wiedner
Abstract:
The MuPix Telescope is a particle tracking telescope, optimized for tracking low momentum particles and high rates. It is based on the novel High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), designed for the Mu3e tracking detector. The telescope represents a first application of the HV-MAPS technology and also serves as test bed of the Mu3e readout chain. The telescope consists of up to eigh…
▽ More
The MuPix Telescope is a particle tracking telescope, optimized for tracking low momentum particles and high rates. It is based on the novel High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), designed for the Mu3e tracking detector. The telescope represents a first application of the HV-MAPS technology and also serves as test bed of the Mu3e readout chain. The telescope consists of up to eight layers of the newest prototypes, the MuPix7 sensors, which send data self-triggered via fast serial links to FPGAs, where the data is time-ordered and sent to the PC. A particle hit rate of 1 MHz per layer could be processed. Online tracking is performed with a subset of the incoming data. The general concept of the telescope, chip architecture, readout concept and online reconstruction are described. The performance of the sensor and of the telescope during test beam measurements are presented.
△ Less
Submitted 9 November, 2016;
originally announced November 2016.
-
MuPix7 - A fast monolithic HV-CMOS pixel chip for Mu3e
Authors:
H. Augustin,
N. Berger,
S. Dittmeier,
J. Hammerich,
U. Hartenstein,
Q. Huang,
L. Huth,
D. Immig,
A. Kozlinskiy,
F. Meier Aeschbacher,
I. Perić,
A. -K. Perrevoort,
A. Schöning,
S. Shrestha,
I. Sorokin,
A. Tyukin,
D. vom Bruch,
F. Wauters,
D. Wiedner,
M. Zimmermann
Abstract:
The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 μm. It provides continuous self-triggered, non-shuttered readout at rates up to 30 Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 μm^2. The hit efficiency depends on the chosen working point. Settings with a power consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution of 14.2 ns (Gaussian…
▽ More
The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 μm. It provides continuous self-triggered, non-shuttered readout at rates up to 30 Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 μm^2. The hit efficiency depends on the chosen working point. Settings with a power consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution of 14.2 ns (Gaussian sigma) is achieved. Latest results from 2016 test beam campaigns are shown.
△ Less
Submitted 10 October, 2016; v1 submitted 7 October, 2016;
originally announced October 2016.
-
The MuPix System-on-Chip for the Mu3e Experiment
Authors:
Heiko Augustin,
Niklaus Berger,
Sebastian Dittmeier,
Carsten Grzesik,
Jan Hammerich,
Qinhua Huang,
Lennart Huth,
Moritz Kiehn,
Alexandr Kozlinskiy,
Frank Meier Aeschbacher,
Ivan Perić,
Ann-Kathrin Perrevoort,
André Schöning,
Shruti Shrestha,
Dorothea vom Bruch,
Frederik Wauters,
Dirk Wiedner
Abstract:
Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $μ^+ \rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\,μ$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field…
▽ More
Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $μ^+ \rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\,μ$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field provides precise vertex and momentum information. The MuPix chip combines pixel sensor cells with integrated analog electronics and a periphery with a complete digital readout. The MuPix7 is the first HV-MAPS prototype implementing all functionalities of the final sensor including a readout state machine and high speed serialization with 1.25 Gbit/s data output, allowing for a streaming readout in parallel to the data taking. The observed efficiency of the MuPix7 chip including the full readout system is $\geq99\%$ in a high rate test beam.
△ Less
Submitted 14 October, 2016; v1 submitted 29 March, 2016;
originally announced March 2016.
-
Modelling a response as a function of high frequency count data: the association between physical activity and fat mass
Authors:
Nicole H. Augustin,
Calum Mattocks,
Julian J. Faraway,
Sonja Greven,
Andy R. Ness
Abstract:
We present a new statistical modelling approach where the response is a function of high frequency count data. Our application is about investigating the relationship between the health outcome fat mass and physical activity (PA) measured by accelerometer. The accelerometer quantifies the intensity of physical activity as counts per epoch over a given period of time. We use data from the Avon long…
▽ More
We present a new statistical modelling approach where the response is a function of high frequency count data. Our application is about investigating the relationship between the health outcome fat mass and physical activity (PA) measured by accelerometer. The accelerometer quantifies the intensity of physical activity as counts per epoch over a given period of time. We use data from the Avon longitudinal study of parents and children (ALSPAC) where accelerometer data is available as a time series of accelerometer counts per minute over seven days for a subset of children. In order to compare accelerometer profiles between individuals and to reduce the high dimension a functional summary of the profiles is used. We use the histogram as a functional summary due to its simplicity, suitability and ease of interpretation. Our model is an extension of generalised regression of scalars on functions or signal regression. It allows also multi-dimensional functional predictors and additive non-linear predictors for metric covariates. The additive multidimensional functional predictors allow investigating specific questions about whether the effect of PA varies over its intensity, by gender, by time of day or by day of the week. The key feature of the model is that it utilises the full profile of measured PA without requiring cut-points defining intensity levels for light, moderate and vigorous activity. We show that the (not necessarily causal) effect of PA is not linear and not constant over the activity intensity. Also, there is little evidence to suggest that the effect of PA intensity varies by gender or whether it happens on weekdays or on weekends.
△ Less
Submitted 17 January, 2014;
originally announced January 2014.
-
A Tracker for the Mu3e Experiment based on High-Voltage Monolithic Active Pixel Sensors
Authors:
Niklaus Berger,
Heiko Augustin,
Sebastian Bachmann,
Moritz Kiehn,
Ivan Perić,
Ann-Kathrin Perrevoort,
Raphael Philipp,
André Schöning,
Kevin Stumpf,
Dirk Wiedner,
Bernd Windelband,
Marco Zimmermann
Abstract:
The Mu3e experiment searches for the lepton flavour violating decay mu+ -> e+e-e+, aiming for a branching fraction sensitivity of 10^-16. This requires an excellent momentum resolution for low energy electrons, high rate capability and a large acceptance. In order to minimize multiple scattering, the amount of material has to be as small as possible. These challenges can be met with a tracker buil…
▽ More
The Mu3e experiment searches for the lepton flavour violating decay mu+ -> e+e-e+, aiming for a branching fraction sensitivity of 10^-16. This requires an excellent momentum resolution for low energy electrons, high rate capability and a large acceptance. In order to minimize multiple scattering, the amount of material has to be as small as possible. These challenges can be met with a tracker built from high-voltage monolithic active pixel sensors (HV-MAPS), which can be thinned to 50 um and which incorporate the complete read-out electronics on the sensor chip. To further minimise material, the sensors are supported by a mechanical structure built from 25 um thick Kapton foil and cooled with gaseous helium.
△ Less
Submitted 30 September, 2013;
originally announced September 2013.