-
Shining Light on the Dark Sector: Search for Axion-like Particles and Other New Physics in Photonic Final States with FASER
Authors:
FASER collaboration,
Roshan Mammen Abraham,
Xiaocong Ai,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Emma Bianchi,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Eunhyung Cho,
Dhruv Chouhan,
Andrea Coccaro,
Stephane D�bieux,
Monica D'Onofrio,
Ansh Desai
, et al. (83 additional authors not shown)
Abstract:
The first FASER search for a light, long-lived particle decaying into a pair of photons is reported. The search uses LHC proton-proton collision data at $\sqrt{s}=13.6~\text{TeV}$ collected in 2022 and 2023, corresponding to an integrated luminosity of $57.7\text{fb}^{-1}$. A model with axion-like particles (ALPs) dominantly coupled to weak gauge bosons is the primary target. Signal events are cha…
▽ More
The first FASER search for a light, long-lived particle decaying into a pair of photons is reported. The search uses LHC proton-proton collision data at $\sqrt{s}=13.6~\text{TeV}$ collected in 2022 and 2023, corresponding to an integrated luminosity of $57.7\text{fb}^{-1}$. A model with axion-like particles (ALPs) dominantly coupled to weak gauge bosons is the primary target. Signal events are characterised by high-energy deposits in the electromagnetic calorimeter and no signal in the veto scintillators. One event is observed, compared to a background expectation of $0.44 \pm 0.39$ events, which is entirely dominated by neutrino interactions. World-leading constraints on ALPs are obtained for masses up to $300~\text{MeV}$ and couplings to the Standard Model W gauge boson, $g_{aWW}$, around $10^{-4}$ GeV$^{-1}$, testing a previously unexplored region of parameter space. Other new particle models that lead to the same experimental signature, including ALPs coupled to gluons or photons, U(1)$_B$ gauge bosons, up-philic scalars, and a Type-I two-Higgs doublet model, are also considered for interpretation, and new constraints on previously viable parameter space are presented in this paper.
△ Less
Submitted 14 October, 2024;
originally announced October 2024.
-
STROBE-X High Energy Modular Array (HEMA)
Authors:
Anthony L. Hutcheson,
Marco Feroci,
Andrea Argan,
Matias Antonelli,
Marco Barbera,
Jorg Bayer,
Pierluigi Bellutti,
Giuseppe Bertuccio,
Valter Bonvicini,
Franck Cadoux,
Riccardo Campana,
Matteo Centis Vignali,
Francesco Ceraudo,
Marc Christophersen,
Daniela Cirrincione,
Fabio D'Anca,
Nicolas De Angelis,
Alessandra De Rosa,
Giovanni Della Casa,
Ettore Del Monte,
Giuseppe Dilillo,
Yuri Evangelista,
Yannick Favre,
Francesco Ficorella,
Mauro Fiorini
, et al. (42 additional authors not shown)
Abstract:
The High Energy Modular Array (HEMA) is one of three instruments that compose the STROBE-X mission concept. The HEMA is a large-area, high-throughput non-imaging pointed instrument based on the Large Area Detector developed as part of the LOFT mission concept. It is designed for spectral timing measurements of a broad range of sources and provides a transformative increase in sensitivity to X-rays…
▽ More
The High Energy Modular Array (HEMA) is one of three instruments that compose the STROBE-X mission concept. The HEMA is a large-area, high-throughput non-imaging pointed instrument based on the Large Area Detector developed as part of the LOFT mission concept. It is designed for spectral timing measurements of a broad range of sources and provides a transformative increase in sensitivity to X-rays in the energy range of 2--30 keV compared to previous instruments, with an effective area of 3.4 m$^{2}$ at 8.5 keV and an energy resolution of better than 300 eV at 6 keV in its nominal field of regard.
△ Less
Submitted 10 October, 2024;
originally announced October 2024.
-
Analysis of commissioning data from SST-1M : A Prototype of Single-Mirror Small Size Telescope
Authors:
Thomas Tavernier,
Jakub Jurysek,
Vladimir Novotn�,
Matthieu Heller,
Dusan Mandat,
Miroslav Pech,
A. Araudo,
C. M. Alispach,
V. Beshley,
J. Blazek,
J. Borkowski,
S. Boula,
T. Bulik,
F. Cadoux,
S. Casanova,
A. Christov,
L. Chytka,
Y. Favre,
T. Gieras,
P. Hamal,
M. Hrabovsky,
M. Jelinek,
V. Karas,
L. Gibaud,
�. Lyard
, et al. (30 additional authors not shown)
Abstract:
SST-1M is a prototype of a single-mirror Small Size Telescope developed by a consortium of institutes from Poland, Switzerland and the Czech Republic. With a wide field of view of 9 degrees, SST-1Ms are designed to detect gamma-rays in the energy range between 1 and 300 TeV. The design of the SST-1M follows the Davies-Cotton concept, with a 9.42m2 multi-segment mirror. SST-1M is equipped with Digi…
▽ More
SST-1M is a prototype of a single-mirror Small Size Telescope developed by a consortium of institutes from Poland, Switzerland and the Czech Republic. With a wide field of view of 9 degrees, SST-1Ms are designed to detect gamma-rays in the energy range between 1 and 300 TeV. The design of the SST-1M follows the Davies-Cotton concept, with a 9.42m2 multi-segment mirror. SST-1M is equipped with DigiCam camera, which features a fully digital readout and trigger system using 250 MHz ADC, and a compact Photo-Detector Plane (PDP) composed of 1296 pixels, each made of a hexagonal light guide coupled to silicone photomultipliers (SiPM).
Two SST-1M telescopes are currently being commissioned at the Ondrejov Observatory in the Czech Republic, where they are successfully observing Cerenkov events in stereo. This contribution will present an overview of calibration strategies and performance evaluation based on data collected at the observatory.
△ Less
Submitted 27 September, 2024;
originally announced September 2024.
-
The SST-1M imaging atmospheric Cherenkov telescope for gamma-ray astrophysics
Authors:
C. Alispach,
A. Araudo,
M. Balbo,
V. Beshley,
A. Biland,
J. Blažek,
J. Borkowski,
T. Bulik,
F. Cadoux,
S. Casanova,
A. Christov,
J. Chudoba,
L. Chytka,
P. Dědič,
D. della Volpe,
Y. Favre,
M. Garczarczyk,
L. Gibaud,
T. Gieras,
P. Hamal,
M. Heller,
M. Hrabovský,
P. Janeček,
M. Jelínek,
V. Jílek
, et al. (40 additional authors not shown)
Abstract:
The SST-1M is a Small-Sized Telescope (SST) designed to provide a cost-effective and high-performance solution for gamma-ray astrophysics, particularly for energies beyond a few TeV. The goal is to integrate this telescope into an array of similar instruments, leveraging its lightweight design, earthquake resistance, and established Davies-Cotton configuration. Additionally, its optical system is…
▽ More
The SST-1M is a Small-Sized Telescope (SST) designed to provide a cost-effective and high-performance solution for gamma-ray astrophysics, particularly for energies beyond a few TeV. The goal is to integrate this telescope into an array of similar instruments, leveraging its lightweight design, earthquake resistance, and established Davies-Cotton configuration. Additionally, its optical system is designed to function without a protective dome, allowing it to withstand the harsh atmospheric conditions typical of mountain environments above 2000 m. The SST-1M utilizes a fully digitizing camera system based on silicon photomultipliers (SiPMs). This camera is capable of digitizing all signals from the UV-optical light detectors, allowing for the implementation of various triggers and data analysis methods. We detail the process of designing, prototyping, and validating this system, ensuring that it meets the stringent requirements for gamma-ray detection and performance. An SST-1M stereo system is currently operational and collecting data at the Ondřejov observatory in the Czech Republic, situated at 500 m. Preliminary results from this system are promising. A forthcoming paper will provide a comprehensive analysis of the performance of the telescopes in detecting gamma rays and operating under real-world conditions.
△ Less
Submitted 17 September, 2024;
originally announced September 2024.
-
Optimizing the light output of a plastic scintillator and SiPM based detector through optical characterization and simulation: A case study for POLAR-2
Authors:
Nicolas De Angelis,
Franck Cadoux,
Coralie Husi,
Merlin Kole,
Sławomir Mianowski
Abstract:
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this kind of detectors are Compton polarimeters such as POLAR-2 or LEAP, for which a low-Z material is needed for the Compton effect to be dominant down to as low ene…
▽ More
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this kind of detectors are Compton polarimeters such as POLAR-2 or LEAP, for which a low-Z material is needed for the Compton effect to be dominant down to as low energy as possible. Such detectors aim to measure low energy Compton depositions which produce small amounts of optical light, and for which optimizing the instrumental optical properties consequently imperative.
The light collection efficiency of such a device was studied with a focus on the POLAR-2 GRB polarimeter, in which the conversion of incoming $γ$-rays into readable signal goes through the production and collection of optical light, which was to be optimized both through measurements and simulations. The optical elements of the POLAR-2 polarimeter prototype module were optically characterized and an optical simulation based on Geant4 was developed to fully model its optical performances. The results from simulations were used to optimize the design and finally to verify its performance. The study resulted in a detector capable of measuring energy depositions of several keV. In addition an important finding of this work is the impact of the plastic scintillator surface roughness on the light collection. It was found that a plastic scintillator with a higher scintillation efficiency but made of a softer material, hence with a rougher surface, was not necessarily the best option to optimize the light collection. Furthermore, in order to optimize the optical crosstalk between different channels, a production technique for very thin ($\sim$150$~μ$m) and reusable silicone-based optical coupling pads, which can be applied for other experiments, was developed.
△ Less
Submitted 15 July, 2024;
originally announced July 2024.
-
Response of the first POLAR-2 Prototype to Polarized Beams
Authors:
Merlin Kole,
Nicolas de Angelis,
Ana Bacelj,
Franck Cadoux,
Agnieszka Elwertowska,
Johannes Hulsman,
Hancheng Li,
Grzegorz Łubian,
Tomasz Kowalski,
Gilles Koziol,
Agnieszka Pollo,
Nicolas Produit,
Dominik Rybka,
Adrien Stil,
Jianchao Sun,
Xin Wu,
Kacper Zezuliński,
Shuang-Nan Zhang
Abstract:
POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016. POLAR-2 aims to measure the polarization of the Gamma-ray Burst prompt emission within the 30-800 keV energy range. Thanks to its high sensitivity to gamma-ray polar…
▽ More
POLAR-2 is a dedicated gamma-ray polarimeter currently foreseen to be launched towards the China Space Station around 2027. The design of the detector is based on the legacy of its predecessor mission POLAR which was launched in 2016. POLAR-2 aims to measure the polarization of the Gamma-ray Burst prompt emission within the 30-800 keV energy range. Thanks to its high sensitivity to gamma-ray polarization, as well as its large effective area, POLAR-2 will provide the most precise measurements of this type to date. Such measurements are key to improve our understanding of the astrophysical processes responsible for Gamma-Ray Bursts. The detector consists of a segmented array of plastic scintillator bars, each one of which is read out by a Silicon PhotoMultiplier channel. The flight model of POLAR-2 will contain a total of 6400 scintillators. These are divided into 100 groups of 64 bars each, in so-called polarimeter modules. In recent years, the collaboration has designed and produced the first prototypes of these polarimeter modules and subjected these to space qualification tests. In addition, in April 2023, the first of these modules were calibrated using fully polarized gamma-ray beams at the European Synchrotron Radiation Facility (ESRF) in France. In this work, we will present the results of this calibration campaign and compare these to the simulated performance of the POLAR-2 modules. Potential improvements to the design are also discussed. Finally, the measurements are used, in combination with the verified simulation framework, to estimate the scientific performance of the full POLAR-2 detector and compare it to its predecessor.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
Testbeam results of irradiated SiGe BiCMOS monolithic silicon pixel detector without internal gain layer
Authors:
T. Moretti,
M. Milanesio,
R. Cardella,
T. Kugathasan,
A. Picardi,
I. Semendyaev,
M. Elviretti,
H. R�cker,
K. Nakamura,
Y. Takubo,
M. Togawa,
F. Cadoux,
R. Cardarelli,
L. Cecconi,
S. D�bieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (5 additional authors not shown)
Abstract:
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a…
▽ More
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a 130 nm SiGe BiCMOS technology process. The dependence on the proton fluence of the efficiency and the time resolution of this prototype was measured with the frontend electronics operated at a power density between 0.13 and 0.9 W/cm2. The testbeam data show that the detection efficiency of 99.96% measured at sensor bias voltage of 200 V before irradiation becomes 96.2% after a fluence of 1 x 1016 neq/cm2. An increase of the sensor bias voltage to 300 V provides an efficiency to 99.7% at that proton fluence. The timing resolution of 20 ps measured before irradiation rises for a proton fluence of 1 x 1016 neq/cm2 to 53 and 45 ps at HV = 200 and 300 V, respectively.
△ Less
Submitted 21 June, 2024; v1 submitted 19 April, 2024;
originally announced April 2024.
-
First Measurement of the $ν_e$ and $ν_μ$ Interaction Cross Sections at the LHC with FASER's Emulsion Detector
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (80 additional authors not shown)
Abstract:
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated lumin…
▽ More
This paper presents the first results of the study of high-energy electron and muon neutrino charged-current interactions in the FASER$ν$ emulsion/tungsten detector of the FASER experiment at the LHC. A subset of the FASER$ν$ volume, which corresponds to a target mass of 128.6~kg, was exposed to neutrinos from the LHC $pp$ collisions with a centre-of-mass energy of 13.6~TeV and an integrated luminosity of 9.5 fb$^{-1}$. Applying stringent selections requiring electrons with reconstructed energy above 200~GeV, four electron neutrino interaction candidate events are observed with an expected background of $0.025^{+0.015}_{-0.010}$, leading to a statistical significance of 5.2$σ$. This is the first direct observation of electron neutrino interactions at a particle collider. Eight muon neutrino interaction candidate events are also detected, with an expected background of $0.22^{+0.09}_{-0.07}$, leading to a statistical significance of 5.7$σ$. The signal events include neutrinos with energies in the TeV range, the highest-energy electron and muon neutrinos ever detected from an artificial source. The energy-independent part of the interaction cross section per nucleon is measured over an energy range of 560--1740 GeV (520--1760 GeV) for $ν_e$ ($ν_μ$) to be $(1.2_{-0.7}^{+0.8}) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$ ($(0.5\pm0.2) \times 10^{-38}~\mathrm{cm}^{2}\,\mathrm{GeV}^{-1}$), consistent with Standard Model predictions. These are the first measurements of neutrino interaction cross sections in those energy ranges.
△ Less
Submitted 15 July, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Neutrino Rate Predictions for FASER
Authors:
FASER Collaboration,
Roshan Mammen Abraham,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Angela Burger,
Franck Cadoux,
Roberto Cardella,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Débieux,
Monica D'Onofrio,
Ansh Desai,
Sergey Dmitrievsky,
Sinead Eley,
Yannick Favre,
Deion Fellers
, et al. (75 additional authors not shown)
Abstract:
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of ne…
▽ More
The Forward Search Experiment (FASER) at CERN's Large Hadron Collider (LHC) has recently directly detected the first collider neutrinos. Neutrinos play an important role in all FASER analyses, either as signal or background, and it is therefore essential to understand the neutrino event rates. In this study, we update previous simulations and present prescriptions for theoretical predictions of neutrino fluxes and cross sections, together with their associated uncertainties. With these results, we discuss the potential for possible measurements that could be carried out in the coming years with the FASER neutrino data to be collected in LHC Run 3 and Run 4.
△ Less
Submitted 13 June, 2024; v1 submitted 20 February, 2024;
originally announced February 2024.
-
Radiation Tolerance of SiGe BiCMOS Monolithic Silicon Pixel Detectors without Internal Gain Layer
Authors:
M. Milanesio,
L. Paolozzi,
T. Moretti,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
I. Semendyaev,
S. Zambito,
K. Nakamura,
Y. Tabuko,
M. Togawa,
M. Elviretti,
H. Rücker,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi
, et al. (5 additional authors not shown)
Abstract:
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted se…
▽ More
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted sensor. Laboratory tests conducted with a 90Sr source show that the detector works satisfactorily after irradiation. The signal-to-noise ratio is not seen to change up to fluence of 6 x 10^14 n_eq /cm^2 . The signal time jitter was estimated as the ratio between the voltage noise and the signal slope at threshold. At -35 {^\circ}C, sensor bias voltage of 200 V and frontend power consumption of 0.9 W/cm^2, the time jitter of the most-probable signal amplitude was estimated to be 21 ps for proton fluence up to 6 x 10 n_eq/cm^2 and 57 ps at 1 x 10^16 n_eq/cm^2 . Increasing the sensor bias to 250 V and the analog voltage of the preamplifier from 1.8 to 2.0 V provides a time jitter of 40 ps at 1 x 10^16 n_eq/cm^2.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
Energy-dependent polarization of Gamma-Ray Bursts' prompt emission with the POLAR and POLAR-2 instruments
Authors:
Nicolas De Angelis,
J. Michael Burgess,
Franck Cadoux,
Jochen Greiner,
Merlin Kole,
Hancheng Li,
Slawomir Mianowski,
Agnieszka Pollo,
Nicolas Produit,
Dominik Rybka,
Jianchao Sun,
Xin Wu,
Shuang-Nan Zhang
Abstract:
Gamma-Ray Bursts are among the most powerful events in the Universe. Despite half a century of observations of these transient sources, many open questions remain about their nature. Polarization measurements of the GRB prompt emission have long been theorized to be able to answer most of these questions. With the aim of characterizing the polarization of these prompt emissions, a compact Compton…
▽ More
Gamma-Ray Bursts are among the most powerful events in the Universe. Despite half a century of observations of these transient sources, many open questions remain about their nature. Polarization measurements of the GRB prompt emission have long been theorized to be able to answer most of these questions. With the aim of characterizing the polarization of these prompt emissions, a compact Compton polarimeter, called POLAR, has been launched to space in September 2016. Time integrated polarization analysis of the POLAR GRB catalog have shown that the prompt emission is lowly polarized or fully unpolarized. However, time resolved analysis depicted strong hints of an evolving polarization angle within single pulses, washing out the polarization degree in time integrated analyses. Here we will for the first time present energy resolved polarization measurements with the POLAR data. The novel analysis, performed on several GRBs, will provide new insights and alter our understanding of GRB polarization. The analysis was performed using the 3ML framework to fit polarization parameters versus energy in parallel to the spectral parameters. Although limited by statistics, the results could provide a very relevant input to disentangle between existing theoretical models. In order to gather more statistics per GRB and perform joint time and energy resolved analysis, a successor instrument, called POLAR-2, is under development with a launch window early 2025 to the CSS. After presenting the first energy resolved polarization results of the POLAR mission, we will present the prospects for such measurements with the upcoming POLAR-2 mission.
△ Less
Submitted 1 September, 2023;
originally announced September 2023.
-
Mono and stereo performance of the two SST-1M telescope prototypes
Authors:
J. Jurysek,
T. Tavernier,
V. Novotn�,
M. Heller,
D. Mandat,
M. Pech,
C. Alispach,
A. Araudo,
V. Beshley,
J. Blazek,
J. Borkowski,
S. Boula,
T. Bulik,
F. Cadoux,
S. Casanova,
A. Christov,
L. Chytka,
D. della Volpe,
Y. Favre,
L. Gibaud,
T. Gieras,
P. Hamal,
M. Hrabovsky,
M. Jel�nek,
V. Karas
, et al. (29 additional authors not shown)
Abstract:
The Single-Mirror Small-Sized Telescope, or SST-1M, was originally developed as a prototype of a small-sized telescope for CTA, designed to form an array for observations of gamma-ray-induced atmospheric showers for energies above 3 TeV. A pair of SST-1M telescopes is currently being commissioned at the Ondrejov Observatory in the Czech Republic, and the telescope capabilities for mono and stereo…
▽ More
The Single-Mirror Small-Sized Telescope, or SST-1M, was originally developed as a prototype of a small-sized telescope for CTA, designed to form an array for observations of gamma-ray-induced atmospheric showers for energies above 3 TeV. A pair of SST-1M telescopes is currently being commissioned at the Ondrejov Observatory in the Czech Republic, and the telescope capabilities for mono and stereo observations are being tested in better astronomical conditions. The final location for the telescopes will be decided based on these tests. In this contribution, we present a data analysis pipeline called sst1mpipe, and the performance of the telescopes when working independently and in a stereo regime.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
First Direct Observation of Collider Neutrinos with FASER at the LHC
Authors:
FASER Collaboration,
Henso Abreu,
John Anders,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jeremy Atkinson,
Florian U. Bernlochner,
Tobias Blesgen,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Ansh Desai,
Sergey Dmitrievsky,
Monica D'Onofrio,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Carlo Alberto Fenoglio,
Didier Ferrere
, et al. (63 additional authors not shown)
Abstract:
We report the first direct observation of neutrino interactions at a particle collider experiment. Neutrino candidate events are identified in a 13.6 TeV center-of-mass energy $pp$ collision data set of 35.4 fb${}^{-1}$ using the active electronic components of the FASER detector at the Large Hadron Collider. The candidates are required to have a track propagating through the entire length of the…
▽ More
We report the first direct observation of neutrino interactions at a particle collider experiment. Neutrino candidate events are identified in a 13.6 TeV center-of-mass energy $pp$ collision data set of 35.4 fb${}^{-1}$ using the active electronic components of the FASER detector at the Large Hadron Collider. The candidates are required to have a track propagating through the entire length of the FASER detector and be consistent with a muon neutrino charged-current interaction. We infer $153^{+12}_{-13}$ neutrino interactions with a significance of 16 standard deviations above the background-only hypothesis. These events are consistent with the characteristics expected from neutrino interactions in terms of secondary particle production and spatial distribution, and they imply the observation of both neutrinos and anti-neutrinos with an incident neutrino energy of significantly above 200 GeV.
△ Less
Submitted 21 August, 2023; v1 submitted 24 March, 2023;
originally announced March 2023.
-
20 ps Time Resolution with a Fully-Efficient Monolithic Silicon Pixel Detector without Internal Gain Layer
Authors:
S. Zambito,
M. Milanesio,
T. Moretti,
L. Paolozzi,
M. Munker,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
M. Elviretti,
H. Rücker,
A. Trusch,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (3 additional authors not shown)
Abstract:
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel…
▽ More
A second monolithic silicon pixel prototype was produced for the MONOLITH project. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by a low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer of 350 Ωcm resistivity were used to produce a fully depleted sensor. Laboratory and testbeam measurements of the analog channels present in the pixel matrix show that the sensor has a 130 V wide bias-voltage operation plateau at which the efficiency is 99.8%. Although this prototype does not include an internal gain layer, the design optimised for timing of the sensor and the front-end electronics provides a time resolutions of 20 ps.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Temperature dependence of radiation damage annealing of Silicon Photomultipliers
Authors:
Nicolas De Angelis,
Merlin Kole,
Franck Cadoux,
Johannes Hulsman,
Tomasz Kowalski,
Sebastian Kusyk,
Slawomir Mianowski,
Dominik Rybka,
Jerome Stauffer,
Jan Swakon,
Damian Wrobel,
Xin Wu
Abstract:
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space base…
▽ More
The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher detection efficiency, insensitivity to magnetic fields and mechanical robustness to launch vibrations. All these features make SiPMs ideal for use on space based experiments where the detectors require to be compact, lightweight and capable of surviving launch conditions. A downside with the use of this novel type of detector in space conditions is its susceptibility to radiation damage. In order to understand the lifetime of SiPMs in space, both the damage sustained due to radiation as well as the subsequent recovery, or annealing, from this damage have to be studied. Here we present these studies for three different types of SiPMs from the Hamamatsu S13360 series. Both their behaviour after sustaining radiation equivalent to 2 years in low earth orbit in a typical mission is presented, as well as the recovery of these detectors while stored in different conditions. The storage conditions varied in temperature as well as in operating voltage. The study found that the annealing depends significantly on the temperature of the detectors with those stored at high temperatures recovering significantly faster and at recovering closer to the original performance. Additionally, no significant effect from a reasonable bias voltage on the annealing was observed. Finally the annealing rate as a function of temperature is presented along with various operating strategies for the future SiPM based astrophysical detector POLAR-2 as well as for future SiPM based space borne missions.
△ Less
Submitted 16 December, 2022;
originally announced December 2022.
-
Testbeam Results of the Picosecond Avalanche Detector Proof-Of-Concept Prototype
Authors:
G. Iacobucci,
S. Zambito,
M. Milanesio,
T. Moretti,
J. Saidi,
L. Paolozzi,
M. Munker,
R. Cardella,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina
, et al. (2 additional authors not shown)
Abstract:
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector…
▽ More
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector provides full efficiency and average time resolution of 30, 25 and 17 ps in the overall pixel area for a power consumption of 0.4, 0.9 and 2.7 W/cm^2, respectively. In this first prototype the time resolution depends significantly on the distance from the center of the pixel, varying at the highest power consumption measured between 13 ps at the center of the pixel and 25 ps in the inter-pixel region.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
The FASER Detector
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Olivier Crespo-Lopez,
Stephane Debieux,
Monica D'Onofrio,
Liam Dougherty,
Candan Dozen,
Abdallah Ezzat,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere
, et al. (72 additional authors not shown)
Abstract:
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned…
▽ More
FASER, the ForwArd Search ExpeRiment, is an experiment dedicated to searching for light, extremely weakly-interacting particles at CERN's Large Hadron Collider (LHC). Such particles may be produced in the very forward direction of the LHC's high-energy collisions and then decay to visible particles inside the FASER detector, which is placed 480 m downstream of the ATLAS interaction point, aligned with the beam collisions axis. FASER also includes a sub-detector, FASER$ν$, designed to detect neutrinos produced in the LHC collisions and to study their properties. In this paper, each component of the FASER detector is described in detail, as well as the installation of the experiment system and its commissioning using cosmic-rays collected in September 2021 and during the LHC pilot beam test carried out in October 2021. FASER will start taking LHC collision data in 2022, and will run throughout LHC Run 3.
△ Less
Submitted 23 July, 2022;
originally announced July 2022.
-
SuperFGD prototype time resolution studies
Authors:
I. Alekseev,
T. Arihara,
V. Baranov,
L. Bartoszek,
L. Bernardi,
A. Blondel,
A. V. Boikov,
M. Buizza-Avanzini,
F. Cadoux,
J. Capó,
J. Cayo,
J. Chakrani,
P. S. Chong,
A. Chvirova,
M. Danilov,
Yu. I. Davydov,
A. Dergacheva,
N. Dokania,
D. Douqa,
O. Drapier,
A. Eguchi,
Y. Favre,
D. Fedorova,
S. Fedotov,
Y. Fujii
, et al. (65 additional authors not shown)
Abstract:
The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the f…
▽ More
The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.
△ Less
Submitted 18 January, 2023; v1 submitted 21 June, 2022;
originally announced June 2022.
-
Picosecond Avalanche Detector -- working principle and gain measurement with a proof-of-concept prototype
Authors:
L. Paolozzi,
M. Munker,
R. Cardella,
M. Milanesio,
Y. Gurimskaya,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
R. Kotitsa,
C. Magliocca,
T. Moretti,
M. Nessi,
A. Pizarro Medina,
J. Sabater Iglesias,
J. Saidi,
M. Vicente Barreto Pinto
, et al. (2 additional authors not shown)
Abstract:
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The si…
▽ More
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The signal is then induced by the secondary charges moving inside a thicker drift region. A proof-of-concept monolithic prototype, consisting of a matrix of hexagonal pixels with 100 $μ$m pitch, has been produced using the 130 nm SiGe BiCMOS process by IHP microelectronics. Measurements on probe station and with a $^{55}$Fe X-ray source show that the prototype is functional and displays avalanche gain up to a maximum electron gain of 23. A study of the avalanche characteristics, corroborated by TCAD simulations, indicates that space-charge effects due to the large primary charge produced by the conversion of X-rays from the $^{55}$Fe source limits the effective gain.
△ Less
Submitted 25 September, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
Authors:
G. Iacobucci,
L. Paolozzi,
P. Valerio,
T. Moretti,
F. Cadoux,
R. Cardarelli,
R. Cardella,
S. Débieux,
Y. Favre,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
F. Martinelli,
M. Milanesio,
M. Münker,
M. Nessi,
A. Picardi,
J. Saidi,
H. Rücker,
M. Vicente Barreto Pinto,
S. Zambito
Abstract:
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% w…
▽ More
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.
△ Less
Submitted 21 January, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
The tracking detector of the FASER experiment
Authors:
FASER Collaboration,
Henso Abreu,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Olivier Crespo-Lopez,
Sergey Dmitrievsky,
Monica D'Onofrio,
Candan Dozen,
Abdallah Ezzat,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Stephen Gibson,
Sergio Gonzalez-Sevilla
, et al. (55 additional authors not shown)
Abstract:
FASER is a new experiment designed to search for new light weakly-interacting long-lived particles (LLPs) and study high-energy neutrino interactions in the very forward region of the LHC collisions at CERN. The experimental apparatus is situated 480 m downstream of the ATLAS interaction-point aligned with the beam collision axis. The FASER detector includes four identical tracker stations constru…
▽ More
FASER is a new experiment designed to search for new light weakly-interacting long-lived particles (LLPs) and study high-energy neutrino interactions in the very forward region of the LHC collisions at CERN. The experimental apparatus is situated 480 m downstream of the ATLAS interaction-point aligned with the beam collision axis. The FASER detector includes four identical tracker stations constructed from silicon microstrip detectors. Three of the tracker stations form a tracking spectrometer, and enable FASER to detect the decay products of LLPs decaying inside the apparatus, whereas the fourth station is used for the neutrino analysis. The spectrometer has been installed in the LHC complex since March 2021, while the fourth station is not yet installed. FASER will start physics data taking when the LHC resumes operation in early 2022. This paper describes the design, construction and testing of the tracking spectrometer, including the associated components such as the mechanics, readout electronics, power supplies and cooling system.
△ Less
Submitted 31 May, 2022; v1 submitted 2 December, 2021;
originally announced December 2021.
-
The trigger and data acquisition system of the FASER experiment
Authors:
FASER Collaboration,
Henso Abreu,
Elham Amin Mansour,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David Casper,
Charlotte Cavanagh,
Xin Chen,
Andrea Coccaro,
Stephane Debieux,
Sergey Dmitrievsky,
Monica D'Onofrio,
Candan Dozen,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Enrico Gamberini,
Edward Karl Galantay
, et al. (59 additional authors not shown)
Abstract:
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction…
▽ More
The FASER experiment is a new small and inexpensive experiment that is placed 480 meters downstream of the ATLAS experiment at the CERN LHC. FASER is designed to capture decays of new long-lived particles, produced outside of the ATLAS detector acceptance. These rare particles can decay in the FASER detector together with about 500-1000 Hz of other particles originating from the ATLAS interaction point. A very high efficiency trigger and data acquisition system is required to ensure that the physics events of interest will be recorded. This paper describes the trigger and data acquisition system of the FASER experiment and presents performance results of the system acquired during initial commissioning.
△ Less
Submitted 10 January, 2022; v1 submitted 28 October, 2021;
originally announced October 2021.
-
A 4pi time-of-flight detector for the ND280/T2K upgrade
Authors:
A. Korzenev,
F. Barao,
S. Bordoni,
D. Breton,
F. Cadoux,
Y. Favre,
M. Khabibullin,
A. Khotyantsev,
Y. Kudenko,
T. Lux,
J. Maalmi,
P. Mermod,
O. Mineev,
F. Sanchez
Abstract:
ND280 is a near detector of the T2K experiment which is located in the J-PARC accelerator complex in Japan. After a decade of fruitful data-taking, ND280 is scheduled for upgrade. The time-of-flight (ToF) detector, which is described in this article, is one of three new detectors that will be installed in the basket of ND280. The ToF detector has a modular structure. Each module represents an arra…
▽ More
ND280 is a near detector of the T2K experiment which is located in the J-PARC accelerator complex in Japan. After a decade of fruitful data-taking, ND280 is scheduled for upgrade. The time-of-flight (ToF) detector, which is described in this article, is one of three new detectors that will be installed in the basket of ND280. The ToF detector has a modular structure. Each module represents an array of 20 plastic scintillator bars which are stacked in a plane of 2.4 x 2.2 m2 area. Six modules of similar construction will be assembled in a cube, thus providing an almost 4pi enclosure for an active neutrino target and two TPCs. The light emitted by scintillator is absorbed by arrays of large-area silicon photo-multipliers (SiPMs) which are attached to both ends of every bar. The readout of SiPMs, shaping and analog sum of individual SiPM signals within the array are performed by a discrete circuit amplifier. An average time resolution of about 0.14 ns is achieved for a single bar when measured with cosmic muons. The detector will be installed in the basket of ND280, where it will be used to veto particle originating outside the neutrino target, improve the particle identification and provide a cosmic trigger for calibration of detectors which are enclosed inside it.
△ Less
Submitted 25 December, 2021; v1 submitted 7 September, 2021;
originally announced September 2021.
-
Development and science perspectives of the POLAR-2 instrument: a large scale GRB polarimeter
Authors:
N. De Angelis,
J. M. Burgess,
F. Cadoux,
J. Greiner,
J. Hulsman,
M. Kole,
H. C. Li,
S. Mianowski,
A. Pollo,
N. Produit,
D. Rybka,
J. Stauffer,
J. C. Sun,
B. B. Wu,
X. Wu,
A. Zadrozny,
S. N. Zhang
Abstract:
Despite several decades of multi-wavelength and multi-messenger spectral observations, Gamma-Ray Bursts (GRBs) remain one of the big mysteries of modern astrophysics. Polarization measurements are essential to gain a more clear and complete picture of the emission processes at work in these extremely powerful transient events. In this regard, a first generation of dedicated gamma-ray polarimeters,…
▽ More
Despite several decades of multi-wavelength and multi-messenger spectral observations, Gamma-Ray Bursts (GRBs) remain one of the big mysteries of modern astrophysics. Polarization measurements are essential to gain a more clear and complete picture of the emission processes at work in these extremely powerful transient events. In this regard, a first generation of dedicated gamma-ray polarimeters, POLAR and GAP, were launched into space in the last decade. After 6 months of operation, the POLAR mission detected 55 GRBs, among which 14 have been analyzed in detail, reporting a low polarization degree and a hint of a temporal evolution of the polarization angle. Starting early 2024 and based on the legacy of the POLAR results, the POLAR-2 instrument will aim to provide a catalog of high quality measurements of the energy and temporal evolution of the GRB polarization thanks to its large and efficient polarimeter. Several spectrometer modules will additionally allow to perform joint spectral and polarization analyzes. The mission is foreseen to make high precision polarization measurements of about 50 GRBs every year on board of the China Space Station (CSS). The technical design of the polarimeter modules will be discussed in detail, as well as the expected scientific performances based on the first results of the developed prototype modules.
△ Less
Submitted 7 September, 2021;
originally announced September 2021.
-
Gamma-Ray Polarization Results of the POLAR Mission and Future Prospects
Authors:
M. Kole,
N. de Angelis,
J. M. Burgess,
F. Cadoux,
J. Greiner,
J. Hulsman,
H. C. Li,
S. Mianowski,
A. Pollo,
N. Produit,
D. Rybka,
J. Stauffer,
J. C. Sun,
B. B. Wu,
X. Wu,
A. Zadrozny,
S. N. Zhang
Abstract:
Despite over 50 years of Gamma-Ray Burst (GRB) observations many open questions remain about their nature and the environments in which the emission takes place. Polarization measurements of the GRB prompt emission have long been theorized to be able to answer most of these questions. The POLAR detector was a dedicated GRB polarimeter developed by a Swiss, Chinese and Polish collaboration. The ins…
▽ More
Despite over 50 years of Gamma-Ray Burst (GRB) observations many open questions remain about their nature and the environments in which the emission takes place. Polarization measurements of the GRB prompt emission have long been theorized to be able to answer most of these questions. The POLAR detector was a dedicated GRB polarimeter developed by a Swiss, Chinese and Polish collaboration. The instrument was launched, together with the second Chinese Space Lab, the Tiangong-2, in September 2016 after which it took 6 months of scientific data. During this period POLAR detected 55 GRBs as well as several pulsars. From the analysis of the GRB polarization catalog we see that the prompt emission is lowly polarized or fully unpolarized. There is, however, the caveat that within single pulses there are strong hints of an evolving polarization angle which washes out the polarization degree in the time integrated analysis. Building on the success of the POLAR mission, the POLAR-2 instrument is currently under development. POLAR-2 is a Swiss, Chinese, Polish and German collaboration and was recently approved for launch in 2024. Thanks to its large sensitivity POLAR-2 will produce polarization measurements of at least 50 GRBs per year with a precision equal or higher than the best results published by POLAR. POLAR-2 thereby aims to make the prompt polarization a standard observable and produce catalogs of the gamma-ray polarization of GRBs. Here we will present an overview of the POLAR mission and all its scientific measurement results. Additionally, we will present an overview of the future POLAR-2 mission, and how it will answer some of the questions raised by the POLAR results.
△ Less
Submitted 7 September, 2021;
originally announced September 2021.
-
First neutrino interaction candidates at the LHC
Authors:
FASER Collaboration,
Henso Abreu,
Yoav Afik,
Claire Antel,
Jason Arakawa,
Akitaka Ariga,
Tomoko Ariga,
Florian Bernlochner,
Tobias Boeckh,
Jamie Boyd,
Lydia Brenner,
Franck Cadoux,
David W. Casper,
Charlotte Cavanagh,
Francesco Cerutti,
Xin Chen,
Andrea Coccaro,
Monica D'Onofrio,
Candan Dozen,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Stephen Gibson,
Sergio Gonzalez-Sevilla
, et al. (51 additional authors not shown)
Abstract:
FASER$ν$ at the CERN Large Hadron Collider (LHC) is designed to directly detect collider neutrinos for the first time and study their cross sections at TeV energies, where no such measurements currently exist. In 2018, a pilot detector employing emulsion films was installed in the far-forward region of ATLAS, 480 m from the interaction point, and collected 12.2 fb$^{-1}$ of proton-proton collision…
▽ More
FASER$ν$ at the CERN Large Hadron Collider (LHC) is designed to directly detect collider neutrinos for the first time and study their cross sections at TeV energies, where no such measurements currently exist. In 2018, a pilot detector employing emulsion films was installed in the far-forward region of ATLAS, 480 m from the interaction point, and collected 12.2 fb$^{-1}$ of proton-proton collision data at a center-of-mass energy of 13 TeV. We describe the analysis of this pilot run data and the observation of the first neutrino interaction candidates at the LHC. This milestone paves the way for high-energy neutrino measurements at current and future colliders.
△ Less
Submitted 26 October, 2021; v1 submitted 13 May, 2021;
originally announced May 2021.
-
POLAR-2: a large scale gamma-ray polarimeter for GRBs
Authors:
J. Hulsman,
N. de Angelis,
J. M. Burgess,
F. Cadoux,
J. Greinerd,
M. Kole,
H. Li,
S. Mianowski,
A. Pollo,
N. Produit,
D. Rybka,
J. Stauffer,
X. Wu,
A. Zadrozny,
S. N. Zhang,
J. Sun,
B. Wu
Abstract:
The prompt emission of GRBs has been investigated for more than 50 years but remains poorly understood. Commonly, spectral and temporal profiles of γ-ray emission are analysed. However, they are insufficient for a complete picture on GRB-related physics. The addition of polarization measurements provides invaluable information towards the understanding of these astrophysical sources. In recent yea…
▽ More
The prompt emission of GRBs has been investigated for more than 50 years but remains poorly understood. Commonly, spectral and temporal profiles of γ-ray emission are analysed. However, they are insufficient for a complete picture on GRB-related physics. The addition of polarization measurements provides invaluable information towards the understanding of these astrophysical sources. In recent years, dedicated polarimeters, such as POLAR and GAP, were built. The former of which observed low levels of polarization as well as a temporal evolution of the polarization angle. It was understood that a larger sample of GRB polarization measurements and time resolved studies are necessary to constrain theoretical models. The POLAR-2 mission aims to address this by increasing the effective area by an order of magnitude compared to POLAR. POLAR-2 is manifested for launch on board the China Space Station in 2024 and will operate for at least 2 years. Insight from POLAR will aid in the improvement of the overall POLAR-2 design. Major improvements (compared to POLAR) will include the replacement of multi-anode PMTs (MAPMTs) with SiPMs, increase in sensitive volume and further technological upgrades. POLAR-2 is projected to measure about 50 GRBs per year with equal or better quality compared to the best seen by POLAR. The instrument design, preliminary results and anticipated scientific potential of this mission will be discussed.
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
Technical design of the phase I Mu3e experiment
Authors:
K. Arndt,
H. Augustin,
P. Baesso,
N. Berger,
F. Berg,
C. Betancourt,
D. Bortoletto,
A. Bravar,
K. Briggl,
D. vom Bruch,
A. Buonaura,
F. Cadoux,
C. Chavez Barajas,
H. Chen,
K. Clark,
P. Cooke,
S. Corrodi,
A. Damyanova,
Y. Demets,
S. Dittmeier,
P. Eckert,
F. Ehrler,
D. Fahrni,
S. Gagneur,
L. Gerritzen
, et al. (80 additional authors not shown)
Abstract:
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the p…
▽ More
The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.
△ Less
Submitted 26 August, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
The SuperFGD Prototype Charged Particle Beam Tests
Authors:
A. Blondel,
M. Bogomilov,
S. Bordoni,
F. Cadoux,
D. Douqa,
K. Dugas,
T. Ekelof,
Y. Favre,
S. Fedotov,
K. Fransson,
R. Fujita,
E. Gramstad,
A. K. Ichikawa,
S. Ilieva,
K. Iwamoto,
C. Jesus-Valls,
C. K. Jung,
S. P. Kasetti,
M. Khabibullin,
A. Khotjantsev,
A. Korzenev,
A. Kostin,
Y. Kudenko,
T. Kutter,
T. Lux
, et al. (25 additional authors not shown)
Abstract:
A novel scintillator detector, the SuperFGD, has been selected as the main neutrino target for an upgrade of the T2K experiment ND280 near detector. The detector design will allow nearly 4π coverage for neutrino interactions at the near detector and will provide lower energy thresholds, significantly reducing systematic errors for the experiment. The SuperFGD is made of optically-isolated scintill…
▽ More
A novel scintillator detector, the SuperFGD, has been selected as the main neutrino target for an upgrade of the T2K experiment ND280 near detector. The detector design will allow nearly 4π coverage for neutrino interactions at the near detector and will provide lower energy thresholds, significantly reducing systematic errors for the experiment. The SuperFGD is made of optically-isolated scintillator cubes of size 10x10x10 mm^3, providing the required spatial and energy resolution to reduce systematic uncertainties for future T2K runs. The SuperFGD for T2K will have close to two million cubes in a 1920x560x1840 mm^3 volume. A prototype made of 24x8x48 cubes was tested at a charged particle beamline at the CERN PS facility. The SuperFGD Prototype was instrumented with readout electronics similar to the future implementation for T2K. Results on electronics and detector response are reported in this paper, along with a discussion of the 3D reconstruction capabilities of this type of detector. Several physics analyses with the prototype data are also discussed, including a study of stopping protons.
△ Less
Submitted 7 September, 2020; v1 submitted 20 August, 2020;
originally announced August 2020.
-
Large scale characterization and calibration strategy of a SiPM-based camera for gamma-ray astronomy
Authors:
C. Alispach,
J. Borkowski,
F. R. Cadoux,
N. De Angelis,
D. Della Volpe,
Y. Favre,
M. Heller,
J. Juryšek,
E. Lyard,
D. Mandat,
L. David M. Miranda,
T. Montaruli,
A. Nagai,
D. Neise,
T. R. Njoh Ekoume,
M. Pech,
P. Rajda,
Y. Renier,
V. Sliusar,
R. Walter,
K. Zietara
Abstract:
The SST-1M is a 4-m diameter mirror Davies-Cotton gamma-ray telescope. It has been designed to cover the energy range above 500 GeV and to be part of an array of telescopes separated by 150-200 m. Its innovative camera is featuring large area hexagonal silicon photo-multipliers as photon detectors and a fully digital trigger and readout system. Here, the strategy and the methods for its calibratio…
▽ More
The SST-1M is a 4-m diameter mirror Davies-Cotton gamma-ray telescope. It has been designed to cover the energy range above 500 GeV and to be part of an array of telescopes separated by 150-200 m. Its innovative camera is featuring large area hexagonal silicon photo-multipliers as photon detectors and a fully digital trigger and readout system. Here, the strategy and the methods for its calibration are presented, together with the obtained results. In particular, the off and on-site calibration strategies are demonstrated on the first camera prototype. The performances of the camera in terms of charge and time resolution are described.
△ Less
Submitted 14 September, 2020; v1 submitted 11 August, 2020;
originally announced August 2020.
-
Technical Proposal: FASERnu
Authors:
FASER Collaboration,
Henso Abreu,
Marco Andreini,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Caterina Bertone,
Jamie Boyd,
Andy Buckley,
Franck Cadoux,
David W. Casper,
Francesco Cerutti,
Xin Chen,
Andrea Coccaro,
Salvatore Danzeca,
Liam Dougherty,
Candan Dozen,
Peter B. Denton,
Yannick Favre,
Deion Fellers,
Jonathan L. Feng,
Didier Ferrere,
Jonathan Gall,
Iftah Galon,
Stephen Gibson
, et al. (47 additional authors not shown)
Abstract:
FASERnu is a proposed small and inexpensive emulsion detector designed to detect collider neutrinos for the first time and study their properties. FASERnu will be located directly in front of FASER, 480 m from the ATLAS interaction point along the beam collision axis in the unused service tunnel TI12. From 2021-23 during Run 3 of the 14 TeV LHC, roughly 1,300 electron neutrinos, 20,000 muon neutri…
▽ More
FASERnu is a proposed small and inexpensive emulsion detector designed to detect collider neutrinos for the first time and study their properties. FASERnu will be located directly in front of FASER, 480 m from the ATLAS interaction point along the beam collision axis in the unused service tunnel TI12. From 2021-23 during Run 3 of the 14 TeV LHC, roughly 1,300 electron neutrinos, 20,000 muon neutrinos, and 20 tau neutrinos will interact in FASERnu with TeV-scale energies. With the ability to observe these interactions, reconstruct their energies, and distinguish flavors, FASERnu will probe the production, propagation, and interactions of neutrinos at the highest human-made energies ever recorded. The FASERnu detector will be composed of 1000 emulsion layers interleaved with tungsten plates. The total volume of the emulsion and tungsten is 25cm x 25cm x 1.35m, and the tungsten target mass is 1.2 tonnes. From 2021-23, 7 sets of emulsion layers will be installed, with replacement roughly every 20-50 1/fb in planned Technical Stops. In this document, we summarize FASERnu's physics goals and discuss the estimates of neutrino flux and interaction rates. We then describe the FASERnu detector in detail, including plans for assembly, transport, installation, and emulsion replacement, and procedures for emulsion readout and analyzing the data. We close with cost estimates for the detector components and infrastructure work and a timeline for the experiment.
△ Less
Submitted 9 January, 2020;
originally announced January 2020.
-
A Mini-Imaging Air Cherenkov Telescope
Authors:
S. Njoh Ekoume,
C. Alispach,
F. Cadoux,
V. Coco,
D. della Volpe,
Y. Favre,
M. Heller,
T. Montaruli,
A. Nagai,
A. Neronov,
Y. Renier,
I. Troyano
Abstract:
In this paper we describe the different software and hardware elements of a mini-telescope for the detection of cosmic rays and gamma-rays using the Cherenkov light emitted by their induced particle showers in the atmosphere. We estimate the physics reach of the standalone mini-telescope and present some results of the measurements done at the Sauverny Observatory of the University of Geneva and a…
▽ More
In this paper we describe the different software and hardware elements of a mini-telescope for the detection of cosmic rays and gamma-rays using the Cherenkov light emitted by their induced particle showers in the atmosphere. We estimate the physics reach of the standalone mini-telescope and present some results of the measurements done at the Sauverny Observatory of the University of Geneva and at the Saint-Luc Observatory, which demonstrate the ability of the telescope to observe cosmic rays with energy above about 100 TeV. Such a mini-telescope can constitute a cost-effective out-trigger array that can surround other gamma-ray telescopes or extended air showers detector arrays. Its development was born out of the desire to illustrate to students and amateurs the cosmic ray and gamma-ray detection from ground, as an example of what is done in experiments using larger telescopes. As a matter of fact, a mini-telescope can be used in outreach night events. While outreach is becoming more and more important in the scientific community to raise interest in the general public, the realisation of the mini-telescope is also a powerful way to train students on instrumentation such as photosensors, their associated electronics, acquisition software and data taking. In particular, this mini-telescope uses silicon photomultipliers (SiPM) and the dedicated ASIC, CITIROC.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Calibration and operation of SiPM-based cameras for gamma-ray astronomy in presence of high night-sky light
Authors:
Imen Al Samarai,
Cyril Martin Alispach,
Matteo Balbo,
Anastasia Maria Barbano,
Vasyl Beshley,
Adrian Biland,
Jiri Blazek,
Jacek Błocki,
Jerzy Borkowski,
Tomek Bulik,
Frank Raphael Cadoux,
Ladislav Chytka,
Victor Coco,
Nicolas De Angelis,
Domenico Della Volpe,
Yannick Favre,
Tomasz Gieras,
Mira Grudzińska,
Petr Hamal,
Matthieu Heller,
Miroslav Hrabovsky,
Jakub Juryšek,
Jerzy Kasperek,
Katarzyna Koncewicz,
Andrzej Kotarba
, et al. (34 additional authors not shown)
Abstract:
The next generation of Cherenkov telescope cameras feature Silicon Photo Multipliers (SiPM), which can guarantee excellent performance and allow for observation also under moonlight, increasing duty-cycle and therefore the physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree optical FoV and a 1296-pixel SiPM camera, has been designed to meet the requirements of the next…
▽ More
The next generation of Cherenkov telescope cameras feature Silicon Photo Multipliers (SiPM), which can guarantee excellent performance and allow for observation also under moonlight, increasing duty-cycle and therefore the physics reach. A 4 m-diameter Davies-Cotton prototype telescope with a 9-degree optical FoV and a 1296-pixel SiPM camera, has been designed to meet the requirements of the next generation of ground-based gamma-ray observatories at the highest energies.
The large-scale production of the telescopes for array deployment has required the development of a fully automated calibration strategy which relies on a dedicated hardware, the Camera Test Setup (CTS). For each camera pixel, the CTS is equipped with two LEDs, one operated in pulsed mode to reproduce signal and one in continuous mode to reproduce night-sky background.
In this contribution we will present the camera calibration strategy, from the laboratory measurement to the on-site monitoring with emphasis on the results obtained with the first camera prototype. In addition, key performances such as charge resolution, time resolution and trigger efficiencies and their degradation with increasing night-sky background level will be presented.
△ Less
Submitted 19 August, 2019;
originally announced August 2019.
-
Detecting and Studying High-Energy Collider Neutrinos with FASER at the LHC
Authors:
FASER Collaboration,
Henso Abreu,
Claire Antel,
Akitaka Ariga,
Tomoko Ariga,
Jamie Boyd,
Franck Cadoux,
David W. Casper,
Xin Chen,
Andrea Coccaro,
Candan Dozen,
Peter B. Denton,
Yannick Favre,
Jonathan L. Feng,
Didier Ferrere,
Iftah Galon,
Stephen Gibson,
Sergio Gonzalez-Sevilla,
Shih-Chieh Hsu,
Zhen Hu,
Giuseppe Iacobucci,
Sune Jakobsen,
Roland Jansky,
Enrique Kajomovitz,
Felix Kling
, et al. (23 additional authors not shown)
Abstract:
Neutrinos are copiously produced at particle colliders, but no collider neutrino has ever been detected. Colliders, and particularly hadron colliders, produce both neutrinos and anti-neutrinos of all flavors at very high energies, and they are therefore highly complementary to those from other sources. FASER, the recently approved Forward Search Experiment at the Large Hadron Collider, is ideally…
▽ More
Neutrinos are copiously produced at particle colliders, but no collider neutrino has ever been detected. Colliders, and particularly hadron colliders, produce both neutrinos and anti-neutrinos of all flavors at very high energies, and they are therefore highly complementary to those from other sources. FASER, the recently approved Forward Search Experiment at the Large Hadron Collider, is ideally located to provide the first detection and study of collider neutrinos. We investigate the prospects for neutrino studies of a proposed component of FASER, FASER$ν$, a 25cm x 25cm x 1.35m emulsion detector to be placed directly in front of the FASER spectrometer in tunnel TI12. FASER$ν$ consists of 1000 layers of emulsion films interleaved with 1-mm-thick tungsten plates, with a total tungsten target mass of 1.2 tons. We estimate the neutrino fluxes and interaction rates at FASER$ν$, describe the FASER$ν$ detector, and analyze the characteristics of the signals and primary backgrounds. For an integrated luminosity of 150 fb$^{-1}$ to be collected during Run 3 of the 14 TeV Large Hadron Collider from 2021-23, and assuming standard model cross sections, approximately 1300 electron neutrinos, 20,000 muon neutrinos, and 20 tau neutrinos will interact in FASER$ν$, with mean energies of 600 GeV to 1 TeV, depending on the flavor. With such rates and energies, FASER will measure neutrino cross sections at energies where they are currently unconstrained, will bound models of forward particle production, and could open a new window on physics beyond the standard model.
△ Less
Submitted 20 February, 2020; v1 submitted 6 August, 2019;
originally announced August 2019.
-
Monte Carlo study of a single SST-1M prototype for the Cherenkov Telescope Array
Authors:
Jakub Jurysek,
Imen Al Samarai,
Cyril Alispach,
Matteo Balbo,
Anastasia Maria Barbano,
Vasyl Beshley,
Adrian Biland,
Jiri Blazek,
Jacek Błocki,
Jerzy Borkowski,
Tomek Bulik,
Frank Raphael Cadoux,
Ladislav Chytka,
Victor Coco,
Nicolas De Angelis,
Domenico Della Volpe,
Yannick Favre,
Tomasz Gieras,
Mira Grudzińska,
Petr Hamal,
Mathieu Heller,
Miroslav Hrabovsky,
Jerzy Kasperek,
Katarzyna Koncewicz,
Andrzej Kotarba
, et al. (34 additional authors not shown)
Abstract:
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope for the Cherenkov Telescope Array observatory and it has been extensively tested in Krakow since 2017. In this contribution we present validation of the Monte Carlo model of the prototype and expected performance in Krakow conditions. We focus on gamma/hadron separation and mono reconstruction of energy and gamma photon ar…
▽ More
The SST-1M telescope was developed as a prototype of a Small-Size-Telescope for the Cherenkov Telescope Array observatory and it has been extensively tested in Krakow since 2017. In this contribution we present validation of the Monte Carlo model of the prototype and expected performance in Krakow conditions. We focus on gamma/hadron separation and mono reconstruction of energy and gamma photon arrival direction using Machine learning methods.
△ Less
Submitted 18 July, 2019;
originally announced July 2019.
-
FASER: ForwArd Search ExpeRiment at the LHC
Authors:
FASER Collaboration,
Akitaka Ariga,
Tomoko Ariga,
Jamie Boyd,
Franck Cadoux,
David W. Casper,
Yannick Favre,
Jonathan L. Feng,
Didier Ferrere,
Iftah Galon,
Sergio Gonzalez-Sevilla,
Shih-Chieh Hsu,
Giuseppe Iacobucci,
Enrique Kajomovitz,
Felix Kling,
Susanne Kuehn,
Lorne Levinson,
Hidetoshi Otono,
Brian Petersen,
Osamu Sato,
Matthias Schott,
Anna Sfyrla,
Jordan Smolinsky,
Aaron M. Soffa,
Yosuke Takubo
, et al. (3 additional authors not shown)
Abstract:
FASER, the ForwArd Search ExpeRiment, is a proposed experiment dedicated to searching for light, extremely weakly-interacting particles at the LHC. Such particles may be produced in the LHC's high-energy collisions in large numbers in the far-forward region and then travel long distances through concrete and rock without interacting. They may then decay to visible particles in FASER, which is plac…
▽ More
FASER, the ForwArd Search ExpeRiment, is a proposed experiment dedicated to searching for light, extremely weakly-interacting particles at the LHC. Such particles may be produced in the LHC's high-energy collisions in large numbers in the far-forward region and then travel long distances through concrete and rock without interacting. They may then decay to visible particles in FASER, which is placed 480 m downstream of the ATLAS interaction point. In this work, we describe the FASER program. In its first stage, FASER is an extremely compact and inexpensive detector, sensitive to decays in a cylindrical region of radius R = 10 cm and length L = 1.5 m. FASER is planned to be constructed and installed in Long Shutdown 2 and will collect data during Run 3 of the 14 TeV LHC from 2021-23. If FASER is successful, FASER 2, a much larger successor with roughly R ~ 1 m and L ~ 5 m, could be constructed in Long Shutdown 3 and collect data during the HL-LHC era from 2026-35. FASER and FASER 2 have the potential to discover dark photons, dark Higgs bosons, heavy neutral leptons, axion-like particles, and many other long-lived particles, as well as provide new information about neutrinos, with potentially far-ranging implications for particle physics and cosmology. We describe the current status, anticipated challenges, and discovery prospects of the FASER program.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Penetrating particle ANalyzer (PAN)
Authors:
X. Wu,
G. Ambrosi,
P. Azzarello,
B. Bergmann,
B. Bertucci,
F. Cadoux,
M. Campbell,
M. Duranti,
M. Ionica,
M. Kole,
S. Krucker,
G. Maehlum,
D. Meier,
M. Paniccia,
L. Pinsky,
C. Plainaki,
S. Pospisil,
T. Stein,
P. A. Thonet,
N. Tomassetti,
A. Tykhonov
Abstract:
PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather an…
▽ More
PAN is a scientific instrument suitable for deep space and interplanetary missions. It can precisely measure and monitor the flux, composition, and direction of highly penetrating particles ($> \sim$100 MeV/nucleon) in deep space, over at least one full solar cycle (~11 years). The science program of PAN is multi- and cross-disciplinary, covering cosmic ray physics, solar physics, space weather and space travel. PAN will fill an observation gap of galactic cosmic rays in the GeV region, and provide precise information of the spectrum, composition and emission time of energetic particle originated from the Sun. The precise measurement and monitoring of the energetic particles is also a unique contribution to space weather studies. PAN will map the flux and composition of penetrating particles, which cannot be shielded effectively, precisely and continuously, providing valuable input for the assessment of the related health risk, and for the development of an adequate mitigation strategy. PAN has the potential to become a standard on-board instrument for deep space human travel.
PAN is based on the proven detection principle of a magnetic spectrometer, but with novel layout and detection concept. It will adopt advanced particle detection technologies and industrial processes optimized for deep space application. The device will require limited mass (~20 kg) and power (~20 W) budget. Dipole magnet sectors built from high field permanent magnet Halbach arrays, instrumented in a modular fashion with high resolution silicon strip detectors, allow to reach an energy resolution better than 10\% for nuclei from H to Fe at 1 GeV/n.
△ Less
Submitted 21 January, 2019; v1 submitted 14 January, 2019;
originally announced January 2019.
-
Detailed polarization measurements of the prompt emission of five Gamma-Ray Bursts
Authors:
Shuang-Nan Zhang,
Merlin Kole,
Tian-Wei Bao,
Tadeusz Batsch,
Tancredi Bernasconi,
Franck Cadoux,
Jun-Ying Chai,
Zi-Gao Dai,
Yong-Wei Dong,
Neal Gauvin,
Wojtek Hajdas,
Mi-Xiang Lan,
Han-Cheng Li,
Lu Li,
Zheng-Heng Li,
Jiang-Tao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Silvio Orsi,
Nicolas Produit,
Martin Pohl,
Dominik Rybka,
Hao-Li Shi,
Li-Ming Song,
Jian-Chao Sun
, et al. (15 additional authors not shown)
Abstract:
Gamma-ray bursts are the strongest explosions in the Universe since the Big Bang, believed to be produced either in forming black holes at the end of massive star evolution or merging of compact objects. Spectral and timing properties of gamma-ray bursts suggest that the observed bright gamma-rays are produced in the most relativistic jets in the Universe; however, the physical properties, especia…
▽ More
Gamma-ray bursts are the strongest explosions in the Universe since the Big Bang, believed to be produced either in forming black holes at the end of massive star evolution or merging of compact objects. Spectral and timing properties of gamma-ray bursts suggest that the observed bright gamma-rays are produced in the most relativistic jets in the Universe; however, the physical properties, especially the structure and magnetic topologies in the jets are still not well known, despite several decades of studies. It is widely believed that precise measurements of the polarization properties of gamma-ray bursts should provide crucial information on the highly relativistic jets. As a result there have been many reports of gamma-ray burst polarization measurements with diverse results, see, however many such measurements suffered from substantial uncertainties, mostly systematic. After the first successful measurements by the GAP and COSI instruments, here we report a statistically meaningful sample of precise polarization measurements, obtained with the dedicated gamma-ray burst polarimeter, POLAR onboard China's Tiangong-2 spacelab. Our results suggest that the gamma-ray emission is at most polarized at a level lower than some popular models have predicted; although our results also show intrapulse evolution of the polarization angle. This indicates that the low polarization degrees could be due to an evolving polarization angle during a gamma-ray burst.
△ Less
Submitted 14 January, 2019;
originally announced January 2019.
-
T2K ND280 Upgrade -- Technical Design Report
Authors:
K. Abe,
H. Aihara,
A. Ajmi,
C. Andreopoulos,
M. Antonova,
S. Aoki,
Y. Asada,
Y. Ashida,
A. Atherton,
E. Atkin,
D. Atti�,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
M. Batkiewicz,
A. Beloshapkin,
V. Berardi,
L. Berns,
S. Bhadra,
J. Bian,
S. Bienstock,
A. Blondel,
J. Boix,
S. Bolognesi
, et al. (359 additional authors not shown)
Abstract:
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve…
▽ More
In this document, we present the Technical Design Report of the Upgrade of the T2K Near Detector ND280. The goal of this upgrade is to improve the Near Detector performance to measure the neutrino interaction rate and to constrain the neutrino interaction cross-sections so that the uncertainty in the number of predicted events at Super-Kamiokande is reduced to about 4%. This will allow to improve the physics reach of the T2K-II project. This goal is achieved by modifying the upstream part of the detector, adding a new highly granular scintillator detector (Super-FGD), two new TPCs (High-Angle TPC) and six TOF planes. Details about the detector concepts, design and construction methods are presented, as well as a first look at the test-beam data taken in Summer 2018. An update of the physics studies is also presented.
△ Less
Submitted 14 October, 2020; v1 submitted 11 January, 2019;
originally announced January 2019.
-
Technical Proposal for FASER: ForwArd Search ExpeRiment at the LHC
Authors:
FASER Collaboration,
Akitaka Ariga,
Tomoko Ariga,
Jamie Boyd,
Franck Cadoux,
David W. Casper,
Francesco Cerutti,
Salvatore Danzeca,
Liam Dougherty,
Yannick Favre,
Jonathan L. Feng,
Didier Ferrere,
Jonathan Gall,
Iftah Galon,
Sergio Gonzalez-Sevilla,
Shih-Chieh Hsu,
Giuseppe Iacobucci,
Enrique Kajomovitz,
Felix Kling,
Susanne Kuehn,
Mike Lamont,
Lorne Levinson,
Hidetoshi Otono,
John Osborne,
Brian Petersen
, et al. (11 additional authors not shown)
Abstract:
FASER is a proposed small and inexpensive experiment designed to search for light, weakly-interacting particles during Run 3 of the LHC from 2021-23. Such particles may be produced in large numbers along the beam collision axis, travel for hundreds of meters without interacting, and then decay to standard model particles. To search for such events, FASER will be located 480 m downstream of the ATL…
▽ More
FASER is a proposed small and inexpensive experiment designed to search for light, weakly-interacting particles during Run 3 of the LHC from 2021-23. Such particles may be produced in large numbers along the beam collision axis, travel for hundreds of meters without interacting, and then decay to standard model particles. To search for such events, FASER will be located 480 m downstream of the ATLAS IP in the unused service tunnel TI12 and be sensitive to particles that decay in a cylindrical volume with radius R=10 cm and length L=1.5 m. FASER will complement the LHC's existing physics program, extending its discovery potential to a host of new, light particles, with potentially far-reaching implications for particle physics and cosmology.
This document describes the technical details of the FASER detector components: the magnets, the tracker, the scintillator system, and the calorimeter, as well as the trigger and readout system. The preparatory work that is needed to install and operate the detector, including civil engineering, transport, and integration with various services is also presented. The information presented includes preliminary cost estimates for the detector components and the infrastructure work, as well as a timeline for the design, construction, and installation of the experiment.
△ Less
Submitted 21 December, 2018;
originally announced December 2018.
-
The enhanced X-ray Timing and Polarimetry mission - eXTP
Authors:
ShuangNan Zhang,
Andrea Santangelo,
Marco Feroci,
YuPeng Xu,
FangJun Lu,
Yong Chen,
Hua Feng,
Shu Zhang,
Søren Brandt,
Margarita Hernanz,
Luca Baldini,
Enrico Bozzo,
Riccardo Campana,
Alessandra De Rosa,
YongWei Dong,
Yuri Evangelista,
Vladimir Karas,
Norbert Meidinger,
Aline Meuris,
Kirpal Nandra,
Teng Pan,
Giovanni Pareschi,
Piotr Orleanski,
QiuShi Huang,
Stephane Schanne
, et al. (125 additional authors not shown)
Abstract:
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In ad…
▽ More
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Module concept and thermo-mechanical studies of the silicon-based TT-PET small-animal scanner
Authors:
Didier Ferrere,
Yves Bandi,
Frank Cadoux,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Sebastien Michal,
Antonio Miucci,
Marzio Nessi,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is developing an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2…
▽ More
The TT-PET collaboration is developing an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity for precise depth-of-interaction measurement. In this paper we present the results of simulation studies for the expected data rate, time-of-flight and spatial resolution, as well as the performance of image reconstruction with and without the use of timing information.
△ Less
Submitted 12 March, 2019; v1 submitted 29 November, 2018;
originally announced December 2018.
-
FASER's Physics Reach for Long-Lived Particles
Authors:
FASER Collaboration,
Akitaka Ariga,
Tomoko Ariga,
Jamie Boyd,
Franck Cadoux,
David W. Casper,
Yannick Favre,
Jonathan L. Feng,
Didier Ferrere,
Iftah Galon,
Sergio Gonzalez-Sevilla,
Shih-Chieh Hsu,
Giuseppe Iacobucci,
Enrique Kajomovitz,
Felix Kling,
Susanne Kuehn,
Lorne Levinson,
Hidetoshi Otono,
Brian Petersen,
Osamu Sato,
Matthias Schott,
Anna Sfyrla,
Jordan Smolinsky,
Aaron M. Soffa,
Yosuke Takubo
, et al. (3 additional authors not shown)
Abstract:
FASER,the ForwArd Search ExpeRiment,is a proposed experiment dedicated to searching for light, extremely weakly-interacting particles at the LHC. Such particles may be produced in the LHC's high-energy collisions and travel long distances through concrete and rock without interacting. They may then decay to visible particles in FASER, which is placed 480 m downstream of the ATLAS interaction point…
▽ More
FASER,the ForwArd Search ExpeRiment,is a proposed experiment dedicated to searching for light, extremely weakly-interacting particles at the LHC. Such particles may be produced in the LHC's high-energy collisions and travel long distances through concrete and rock without interacting. They may then decay to visible particles in FASER, which is placed 480 m downstream of the ATLAS interaction point. In this work we briefly describe the FASER detector layout and the status of potential backgrounds. We then present the sensitivity reach for FASER for a large number of long-lived particle models, updating previous results to a uniform set of detector assumptions, and analyzing new models. In particular, we consider all of the renormalizable portal interactions, leading to dark photons, dark Higgs bosons, and heavy neutral leptons (HNLs); light B-L and $L_i - L_j$ gauge bosons; axion-like particles (ALPs) that are coupled dominantly to photons, fermions, and gluons through non-renormalizable operators; and pseudoscalars with Yukawa-like couplings. We find that FASER and its follow-up, FASER 2, have a full physics program, with discovery sensitivity in all of these models and potentially far-reaching implications for particle physics and cosmology.
△ Less
Submitted 15 May, 2019; v1 submitted 29 November, 2018;
originally announced November 2018.
-
The Large Area Detector onboard the eXTP mission
Authors:
Marco Feroci,
Mahdi Ahangarianabhari,
Giovanni Ambrosi,
Filippo Ambrosino,
Andrea Argan,
Marco Barbera,
Joerg Bayer,
Pierluigi Bellutti,
Bruna Bertucci,
Giuseppe Bertuccio,
Giacomo Borghi,
Enrico Bozzo,
Franck Cadoux,
Riccardo Campana,
Francesco Ceraudo,
Tianxiang Chen,
Daniela Cirrincione,
Alessandra De Rosa,
Ettore Del Monte,
Sergio Di Cosimo,
Sebastian Diebold,
Yuri Evangelista,
Qingmei Fan,
Yannick Favre,
Francesco Ficorella
, et al. (46 additional authors not shown)
Abstract:
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Det…
▽ More
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.
△ Less
Submitted 30 July, 2018;
originally announced July 2018.
-
In-flight performance of the DAMPE silicon tracker
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
F. Loparco
, et al. (17 additional authors not shown)
Abstract:
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mech…
▽ More
DAMPE (DArk Matter Particle Explorer) is a spaceborne high-energy cosmic ray and gamma-ray detector, successfully launched in December 2015. It is designed to probe astroparticle physics in the broad energy range from few GeV to 100 TeV. The scientific goals of DAMPE include the identification of possible signatures of Dark Matter annihilation or decay, the study of the origin and propagation mechanisms of cosmic-ray particles, and gamma-ray astronomy. DAMPE consists of four sub-detectors: a plastic scintillator strip detector, a Silicon-Tungsten tracKer-converter (STK), a BGO calorimeter and a neutron detector. The STK is composed of six double layers of single-sided silicon micro-strip detectors interleaved with three layers of tungsten for photon conversions into electron-positron pairs. The STK is a crucial component of DAMPE, allowing to determine the direction of incoming photons, to reconstruct tracks of cosmic rays and to estimate their absolute charge (Z). We present the in-flight performance of the STK based on two years of in-flight DAMPE data, which includes the noise behavior, signal response, thermal and mechanical stability, alignment and position resolution.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
In-Orbit Instrument Performance Study and Calibration for POLAR Polarization Measurements
Authors:
Zhengheng Li,
Merlin Kole,
Jianchao Sun,
Liming Song,
Nicolas Produit,
Bobing Wu,
Tianwei Bao,
Tancredi Bernasconi,
Franck Cadoux,
Yongwei Dong,
Minzi Feng,
Neal Gauvin,
Wojtek Hajdas,
Hancheng Li,
Lu Li,
Xin Liu,
Radoslaw Marcinkowski,
Martin Pohl,
Dominik K. Rybka,
Haoli Shi,
Jacek Szabelski,
Teresa Tymieniecka,
Ruijie Wang,
Yuanhao Wang,
Xing Wen
, et al. (8 additional authors not shown)
Abstract:
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the…
▽ More
POLAR is a compact space-borne detector designed to perform reliable measurements of the polarization for transient sources like Gamma-Ray Bursts in the energy range 50-500keV. The instrument works based on the Compton Scattering principle with the plastic scintillators as the main detection material along with the multi-anode photomultiplier tube. POLAR has been launched successfully onboard the Chinese space laboratory TG-2 on 15th September, 2016. In order to reliably reconstruct the polarization information a highly detailed understanding of the instrument is required for both data analysis and Monte Carlo studies. For this purpose a full study of the in-orbit performance was performed in order to obtain the instrument calibration parameters such as noise, pedestal, gain nonlinearity of the electronics, threshold, crosstalk and gain, as well as the effect of temperature on the above parameters. Furthermore the relationship between gain and high voltage of the multi-anode photomultiplier tube has been studied and the errors on all measurement values are presented. Finally the typical systematic error on polarization measurements of Gamma-Ray Bursts due to the measurement error of the calibration parameters are estimated using Monte Carlo simulations.
△ Less
Submitted 28 May, 2018; v1 submitted 19 May, 2018;
originally announced May 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Internal alignment and position resolution of the silicon tracker of DAMPE determined with orbit data
Authors:
A. Tykhonov,
G. Ambrosi,
R. Asfandiyarov,
P. Azzarello,
P. Bernardini,
B. Bertucci,
A. Bolognini,
F. Cadoux,
A. D'Amone,
A. De Benedittis,
I. De Mitri,
M. Di Santo,
Y. F. Dong,
M. Duranti,
D. D'Urso,
R. R. Fan,
P. Fusco,
V. Gallo,
M. Gao,
F. Gargano,
S. Garrappa,
K. Gong,
M. Ionica,
D. La Marra,
S. J. Lei
, et al. (18 additional authors not shown)
Abstract:
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be…
▽ More
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m$^2$. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.
△ Less
Submitted 22 March, 2018; v1 submitted 7 December, 2017;
originally announced December 2017.
-
In-flight energy calibration of the space-borne Compton polarimeter POLAR
Authors:
Hualin Xiao,
Wojtek Hajdas,
Bobing Wu,
Nicolas Produit,
Jianchao Sun,
Merlin Kole,
Tianwei Bao,
Tancredi Bernasconi,
Tadeusz Batsch,
Franck Cadoux,
Junying Chai,
Yongwei Dong,
Ken Egli,
Neal Gauvin,
Minnan Kong,
Reinhold Kramert,
Siwei Kong,
Hancheng Li,
Lu Li,
Zhengheng Li,
Jiangtao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Silvio Orsi,
Dominik K. Rybka
, et al. (17 additional authors not shown)
Abstract:
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the…
▽ More
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.
△ Less
Submitted 5 June, 2018; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Design and construction of the POLAR detector
Authors:
N. Produit,
T. W. Bao,
T. Batsch,
T. Bernasconi,
I. Britvich,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
M. Kole,
M. N. Kong,
R. Kramert,
L. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin,
D. Rybka,
A. Rutczynska,
H. L. Shi,
P. Socha
, et al. (13 additional authors not shown)
Abstract:
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The co…
▽ More
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The construction of the instrument components is described in this article. Details are provided on problems encountered during the construction phase and their solutions. Initial performance of the instrument in orbit is as expected from ground tests and Monte Carlo simulation.
△ Less
Submitted 28 September, 2017; v1 submitted 21 September, 2017;
originally announced September 2017.