Destructive breakdown studies of irradiated LGADs at beam tests for the ATLAS HGTD
Authors:
L. A. Beresford,
D. E. Boumediene,
L. Castillo Garc�a,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
H. El Jarrari,
A. Eshkevarvakili,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
G. Kramberger,
O. Kurdysh,
R. Mazini,
M. Missio,
M. Morenas,
O. Perrin,
V. Raskina,
G. Saito,
S. Trincaz-Duvoid
Abstract:
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from…
▽ More
In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from various producers were tested in two test beam facilities, DESY (Hamburg) and CERN-SPS (Geneva), as part of ATLAS High Granularity Timing Detector (HGTD) beam tests. The samples were placed in the beam and kept under bias over a long period of time in order to reach a high number of particles crossing each sensor. Both beam tests lead to a similar conclusion, that these destructive events begin to occur when the average electric field in the sensor becomes larger than 12 Volts per micrometre.
△ Less
Submitted 14 July, 2023; v1 submitted 21 June, 2023;
originally announced June 2023.
-
Performance of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector
Authors:
C. Agapopoulou,
L. A. Beresford,
D. E. Boumediene,
L. Castillo Garc�a,
S. Conforti,
C. de la Taille,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
P. Dinaucourt,
A. Falou,
V. Gautam,
D. Gong,
C. Grieco,
S. Grinstein,
S. Guindon,
A. Howard,
O. Kurdysh,
E. Kuwertz,
C. Li,
N. Makovec,
B. Markovic,
G. Martin-Chassal,
R. Mazzini,
C. Milke,
M. Morenas
, et al. (12 additional authors not shown)
Abstract:
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (t…
▽ More
This paper presents the design and characterisation of a front-end prototype ASIC for the ATLAS High Granularity Timing Detector, which is planned for the High-Luminosity phase of the LHC. This prototype, called ALTIROC1, consists of a 5$\times$5-pad matrix and contains the analog part of the single-channel readout (preamplifier, discriminator, two TDCs and SRAM). Two preamplifier architectures (transimpedance and voltage) were implemented and tested. The ASIC was characterised both alone and as a module when connected to a 5$\times$5-pad array of LGAD sensors. In calibration measurements, the ASIC operating alone was found to satisfy the technical requirements for the project, with similar performances for both preamplifier types. In particular, the jitter was found to be 15$\pm$1~ps (35$\pm$1~ps) for an injected charge of 10~fC (4~fC). A degradation in performance was observed when the ASIC was connected to the LGAD array. This is attributed to digital couplings at the entrance of the preamplifiers. When the ASIC is connected to the LGAD array, the lowest detectable charge increased from 1.5~fC to 3.4~fC. As a consequence, the jitter increased for an injected charge of 4~fC. Despite this increase, ALTIROC1 still satisfies the maximum jitter specification (below 65~ps) for the HGTD project. This coupling issue also affects the time over threshold measurements and the time-walk correction can only be performed with transimpedance preamplifiers. Beam test measurements with a pion beam at CERN were also undertaken to evaluate the performance of the module. The best time resolution obtained using only ALTIROC TDC data was 46.3$\pm$0.7~ps for a restricted time of arrival range where the coupling issue is minimized. The residual time-walk contribution is equal to 23~ps and is the dominant electronic noise contribution to the time resolution at 15~fC.
△ Less
Submitted 25 July, 2023; v1 submitted 15 June, 2023;
originally announced June 2023.
-
Performance in beam tests of Carbon-enriched irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector
Authors:
S. Ali,
H. Arnold,
S. L. Auwens,
L. A. Beresford,
D. E. Boumediene,
A. M. Burger,
L. Cadamuro,
L. Castillo Garc�a,
L. D. Corpe,
M. J. Da Cunha Sargedas de Sousa,
D. Dannheim,
V. Dao,
A. Gabrielli,
Y. El Ghazali,
H. El Jarrari,
V. Gautam,
S. Grinstein,
J. Guimar�es da Costa,
S. Guindon,
X. Jia,
G. Kramberger,
Y. Liu,
K. Ma,
N. Makovec,
S. Manzoni
, et al. (12 additional authors not shown)
Abstract:
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation env…
▽ More
The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation environment, LGADs have been optimized by adding carbon in the gain layer, thus reducing the acceptor removal rate after irradiation. Performances of several carbon-enriched LGAD sensors from different vendors, and irradiated with high fluences of 1.5 and 2.5 x 10^15 neq/cm2, have been measured in beam test campaigns during the years 2021 and 2022 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few um. Collected charge, time resolution and hit efficiency measurements are presented. In addition, the efficiency uniformity is also studied as a function of the position of the incident particle inside the sensor pad.
△ Less
Submitted 17 March, 2023; v1 submitted 14 March, 2023;
originally announced March 2023.