-
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils i…
▽ More
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.
△ Less
Submitted 3 April, 2024;
originally announced April 2024.
-
Optimal operation of cryogenic calorimeters through deep reinforcement learning
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an…
▽ More
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.
△ Less
Submitted 25 November, 2023;
originally announced November 2023.
-
Detector development for the CRESST experiment
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum,
M. Kaznacheeva
, et al. (33 additional authors not shown)
Abstract:
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of t…
▽ More
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment, this signal is characterised by a significant increase of events below 200 eV. As the origin of this background is still unknown, it became necessary to develop new detector designs to reach a better understanding of the observations. Within the CRESST collaboration, three new different detector layouts have been developed and they are presented in this contribution.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
Authors:
A. Erhart,
V. Wagner,
A. Wex,
C. Goupy,
D. Lhuillier,
E. Namuth,
C. Nones,
R. Rogly,
V. Savu,
M. Schwarz,
R. Strauss,
M. Vivier,
H. Abele,
G. Angloher,
A. Bento,
J. Burkhart,
L. Canonica,
F. Cappella,
N. Casali,
R. Cerulli,
A. Cruciani,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer
, et al. (37 additional authors not shown)
Abstract:
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we…
▽ More
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Light Dark Matter Search Using a Diamond Cryogenic Detector
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (34 additional authors not shown)
Abstract:
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. W…
▽ More
Diamond operated as a cryogenic calorimeter is an excellent target for direct detection of low-mass dark matter candidates. Following the realization of the first low-threshold cryogenic detector that uses diamond as absorber for astroparticle physics applications, we now present the resulting exclusion limits on the elastic spin-independent interaction cross-section of dark matter with diamond. We measured two 0.175 g CVD (Chemical Vapor Deposition) diamond samples, each instrumented with a W-TES. Thanks to the energy threshold of just 16.8 eV of one of the two detectors, we set exclusion limits on the elastic spin-independent interaction of dark matter particles with carbon nuclei down to dark matter masses as low as 0.122 GeV/c2. This work shows the scientific potential of cryogenic detectors made from diamond and lays the foundation for the use of this material as target for direct detection dark matter experiments.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors
Authors:
CRAB collaboration,
G. Soum-Sidikov,
H. Abele,
J. Burkhart,
F. Cappella,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
J-P. Crocombette,
G. del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
E. Dumonteil,
A. Erhart,
A. Giuliani,
C. Goupy,
F. Gunsing,
E. Jericha,
M. Kaznacheeva,
A. Kinast,
H. Kluck,
A. Langenkämper,
T. Lasserre
, et al. (25 additional authors not shown)
Abstract:
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay betwe…
▽ More
The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
Authors:
CRESST Collaboration,
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff
, et al. (36 additional authors not shown)
Abstract:
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Re…
▽ More
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.
△ Less
Submitted 25 July, 2023; v1 submitted 27 March, 2023;
originally announced March 2023.
-
Towards an automated data cleaning with deep learning in CRESST
Authors:
G. Angloher,
S. Banik,
D. Bartolot,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
S. Gerster,
P. Gorla,
P. V. Guillaumon,
S. Gupta
, et al. (40 additional authors not shown)
Abstract:
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. Wit…
▽ More
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.
△ Less
Submitted 7 January, 2023; v1 submitted 1 November, 2022;
originally announced November 2022.
-
Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (36 additional authors not shown)
Abstract:
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-b…
▽ More
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.
△ Less
Submitted 24 January, 2023; v1 submitted 22 August, 2022;
originally announced September 2022.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Translation of an article by Paul Drude in 1904
Authors:
A. J. Sederberg,
J. Burkhart,
F. Apfelbeck,
B. H. McGuyer
Abstract:
English translation of P. Drude, Annalen der Physik 13, 512 (1904), an article by Paul Drude about Tesla transformers and wireless telegraphy. Includes a discussion of the derivation of an equivalent circuit and the prediction of nonreciprocal mutual inductance for Tesla transformers in the article, which is supplementary material for B. McGuyer, PLoS ONE 9, e115397 (2014).
English translation of P. Drude, Annalen der Physik 13, 512 (1904), an article by Paul Drude about Tesla transformers and wireless telegraphy. Includes a discussion of the derivation of an equivalent circuit and the prediction of nonreciprocal mutual inductance for Tesla transformers in the article, which is supplementary material for B. McGuyer, PLoS ONE 9, e115397 (2014).
△ Less
Submitted 8 June, 2015; v1 submitted 6 March, 2013;
originally announced March 2013.